background image

E

E

N

N

G

G

L

L

I

I

S

S

H

H

72

LECOASPIRA GENIUS

recommend always using the parquet
function with the universal brush (E), to-
gether with the liquid suction insert (E3)
or with the insert for fitted carpet (E4),
wrapped in a parquet cloth with velcro
(E7).

NOTE: 

suction speed and steam quantity are

preset and cannot be adjusted manually.

P

P

R

R

O

O

G

G

R

R

A

A

M

M

M

M

E

E

 

 

P

P

3

3

:

:

 

 

G

G

L

L

A

A

S

S

S

S

 

 

/

/

 

 

M

M

I

I

R

R

R

R

O

O

R

R

S

S

 

 

/

/

T

T

I

I

L

L

E

E

S

S

 

 

/

/

 

 

C

C

E

E

R

R

A

A

M

M

I

I

C

C

When cleaning glass in cold weather, preheat
the glass by starting to dispense steam about
50 cm from the glass surface.. 
• Using the small nozzle (

N

) with the window-

cleaning fitting (

O

or 

O1

), start up the pro-

gramme by pressing the Steam request but-
ton (

A5

) and holding it down to start applying

steam to the glass.

• Apply plenty of steam to the surface to be

cleaned.

• When you release the button (

A5

) and in any

case after a maximum of 30 seconds, suctio-
ning will automatically begin.

• Suctioning stops automatically after an

amount of time proportionate to the time for
which steam is dispensed. In any case you
can stop the programme manually by pres-
sing the suction button (

A4

).

• When cleaning very large surfaces, you may

start the programme again as soon as it is
completed to finish cleaning the entire sur-
face.

• When you have completed the cycle, you

can start suctioning manually by pressing
button (

A4

) to get rid of any remaining damp

on areas adjacent to the treated surface.

NOTE:

suction speed and steam quantity are

preset and cannot be manually adjusted.

P

P

R

R

O

O

G

G

R

R

A

A

M

M

M

M

E

E

 

 

P

P

4

4

:

:

 

 

L

L

O

O

C

C

A

A

L

L

I

I

S

S

E

E

D

D

 

 

S

S

T

T

A

A

I

I

N

N

S

S

/

/

 

 

D

D

E

E

P

P

O

O

S

S

I

I

T

T

S

S

 

 

/

/

 

 

G

G

A

A

P

P

S

S

 

 

B

B

E

E

T

T

W

W

E

E

E

E

N

N

 

 

T

T

I

I

L

L

E

E

S

S

• Assemble the 120° tool (

K

).

• Start the programme by pressing the Steam

request button (

A5

) and holding it down.

• Apply steam to the surface to be treated.
• When you release the button (

A5

) and in any

case after a maximum of 20 seconds, suctio-
ning will begin automatically.

• Suctioning stops automatically after an

amount of time proportionate to the time for

which steam is dispensed. In any case you
can stop the programme manually by pres-
sing the suction button (

A4

).

• When you have completed the cycle, you

can start suctioning manually by pressing
button (

A4

) to get rid of any remaining damp

on areas adjacent to the treated surface.

• To remove stubborn stains or deposits, you

may apply a coloured brush to the 120° tool.
This combines the action of steam with the
mechanical action of the bristles.

NOTE:

suction speed and steam quantity are

preset and cannot be manually adjusted.

P

P

R

R

O

O

G

G

R

R

A

A

M

M

M

M

E

E

 

 

P

P

5

5

:

:

 

 

U

U

P

P

H

H

O

O

L

L

S

S

T

T

E

E

R

R

Y

Y

 

 

/

/

W

W

A

A

L

L

L

L

P

P

A

A

P

P

E

E

R

R

 

 

/

/

 

 

V

V

E

E

H

H

I

I

C

C

L

L

E

E

 

 

I

I

N

N

T

T

E

E

R

R

I

I

O

O

R

R

S

S

• Hold down the Steam request button (

A5

) to

dispense alternating steam cycles and start
suctioning. Release the button (

A5

) to stop

dispensing steam, while suctioning will conti-
nue for a few more seconds to allow the
steam cleaned surface to dry.

• Use the small nozzle (

N

) with the bristle fit-

ting (

P

) and the terry-cloth cover (

E6

).

NOTE: 

suction speed and steam quantity are

preset and cannot be manually adjusted.
Vacuum up hair and dust in manual (

MA

) mode

before steam cleaning surfaces.

P

P

R

R

O

O

G

G

R

R

A

A

M

M

M

M

E

E

 

 

P

P

6

6

:

:

 

 

B

B

E

E

D

D

S

S

 

 

/

/

M

M

A

A

T

T

T

T

R

R

E

E

S

S

S

S

E

E

S

S

• Use the small nozzle (

N

) with the bristle fit-

ting (

P

) and the terry-cloth cover (

E6

).

• Start the programme by pressing the steam

request button (

A5

) and holding it down.

• Apply steam to the surface to be treated.
• When you release the button (

A5

) or in any

case after a maximum of 60 seconds, suctio-
ning will begin automatically.

• Suctioning stops automatically after an

amount of time proportionate to the time for
which steam is dispensed. In any case you
can stop the programme manually by pres-
sing the suction button (

A4

).

NOTE:

suction speed and steam quantity are

preset and cannot be manually adjusted.
Vacuum up hair and dust in manual (

MA

) mode

before steam cleaning surfaces.

LECOASPIRA GENIUS - M0S09128 1Q01:Layout 1

19/01/2010

12.23

Pagina 72

Summary of Contents for VAPORETTO LECOASPIRA GENIUS

Page 1: ...Fig Fig Fig Fig Fig...

Page 2: ...E5 24 25 26 23 17 27 13 14 15 16 18 19 22 20 20 A V 12 1 6 10 7 9 11 8 3 2 8G 8E 8C 8A 8D 8H 8F 5 4 8B E6 B3 B1 B2 A5 A1 A3 A4 A2 U K K1 L E E1 E1 E3 E4 E2 D C N P O O1...

Page 3: ...Q Q W1 W2 W4 B3 B2 W5 T F Q M R S G W3 W W Vaporetto Lecoaspira Genius M0S09128 Edizione 1Q01 1 11 X X1 Y Y1 Z E7 TB TB1...

Page 4: ...Fig 2 Fig 3 Fig 4 Fig 5 Fig 7 Fig 9 Fig 6a Fig 6 Fig 8 Fig 10 Fig 11a Fig 11b MAX Fig 1 Fig 12 Fig 14 Fig 13 Fig E 2 1 Fig A Fig D Fig B Fig C...

Page 5: ...Locking button of the monobloc plug C Accessory locknut D Flexible steam suction tubes E Universal brush E1 Frame lock slides E2 Bristle fitting E3 Liquid suction inserts E4 Insert for fitted carpet E...

Page 6: ...solve any cleaning problem quickly and easily The appliance s controls are on the handle for immediate control without bending down The bright LCD display allows you to see all Vaporetto Lecoaspira s...

Page 7: ...is a danger of explosions is prohibited Do not use the product with toxic sub stances Do not lay the hot appliance on surfaces sensitive to heat Do not leave the appliance exposed to wind or rain Do...

Page 8: ...tched off before connecting the appliance to the mains The iron must be used and rested on a sta ble surface When placing the iron on its stand make sure that the surface on which the stand is placed...

Page 9: ...the Eco ActiveFilter water filter assembly 23 Fill the dirt container 20 with about 1 2 litres of simple tap water until the MAX level indi cator 21 is reached as in fig 5 Put the filter assembly 23...

Page 10: ...controls Simply press the suction button A4 to start vacuuming Hold down the suction button A4 to select the appropriate speed for the surface to be cleaned As suction power increases the number of in...

Page 11: ...ase after a maximum of 20 seconds suctio ning will begin automatically Suctioning stops automatically after an amount of time proportionate to the time for which steam is dispensed In any case you can...

Page 12: ...e Centres and in the best appliance shops Connect the iron B2 to the monobloc plug as described on the section on Operation The amount of steam dispensed may be con trolled manually to suit your requi...

Page 13: ...the sec tion on advice for use of accessories Press the suction button A4 to start suctio ning at maximum power press the suction button A4 again to stop suctioning This programme also effectively rem...

Page 14: ...R OTHER PRODUCTS IN THE STEAM GENE RATOR TANK BUT ONLY IN THE DIRT CON TAINER 20 To ensure the proper operation of the appliance during suction Polti recommends using Bioe cologico inside the dirt con...

Page 15: ...tc When cleaning glass surfaces in particularly cold weather preheat glass with steam from a distance of about 50 cm Spray plants from a distance of at least 50 cm S ST TE EA AM M A AN ND D S SU UC CT...

Page 16: ...hooking them up using the locknut These accessories may be used with the pro gramme P0 or with the programme MA for suction use only IMPORTANT in this case it is important to disable the steam functio...

Page 17: ...m to prevent deformation Periodically check the condition of the gaskets in the monobloc plug B2 and replace them if necessary Also check the seals connecting the extension tubes D and the handle A2 W...

Page 18: ...suction speed indicators 8C and suction indicator 8E flash The liquid level in the water container is too high The selected power level is too high for the surface being cleaned Proceed as described i...

Reviews: