Polocool HN 10C User Manual Download Page 4

3

INTRODUCTION

This portable air conditioner can alter the room temperature and humidity.  It has multiple functions of cooling 
dehumidifying (drying) and fan ventilation, and can be moved from room to room and transported from building to 
building easily.

The air conditioner can maintain set room indoor air temperatures between 18°C and 32°C. The set room 
temperature is displayed on the remote control and in the control panel on the unit. This does not mean that the air 
conditioner will  necessarily reduce the actual room temperature to the set room temperature.

This Polocool HN10C portable refrigerated air conditioner has a maximum cooling capacity of 10,000 BTU or 2.9kW. 
It is suitable to cool rooms up to 17 square metres of floor area in ideal conditions.

This air conditioner incorporates the latest mist motor technology which means the water tray will never need 
emptying, even in extremely humid conditions.

In dehumidifying mode the mist motor does not operate and the drain house can be connected to drain excess 
water and ensure the water tray only needs occasional emptying.

GUIDELINES FOR OPTIMISING COOLING EFFECTIVENESS

 

•  Do not place the air conditioner or plastic window slider in direct sunlight. Close all curtains in the room being 

cooled.

 

•  For maximum cooling press the POWERFUL button on the remote control (see page 10)  – the appliance 

operates in cool mode at maximum fan speed. While this function is selected it is not possible to set the 

temperature or change fan speed. 

 

•  After approximately three minutes of operation the compressor will turn on and cooled air will come out of the 

front air outlet. Hot air will also come out of the exhaust hose

 

•  In COOLING MODE the air conditioner will not cool unless the set temperature is below the existing room 

temperature

 

•  In COOLING MODE once the existing room temperature reaches the set temperature , the fan continues 

operating and the compressor switches on and off to maintain the set temperature within the room.

 

•  For maximum cooling output keep the exhaust hose as straight as possible. Minimise bends which can 

reduce the maximum cooling capacity of the air conditioner.

 

•  Make sure the air intake and outlet grills are unobstructed.

 

• Clean the filters at least once every two weeks

Summary of Contents for HN 10C

Page 1: ...igerated air conditioners are imported and distributed throughout Australasia by POLO Any enquiries should be directed to Polo on 1 800 087 840 in the first instance PORTABLE REFRIGERATED AIR CONDITIO...

Page 2: ...control panel or the remote control Do not connect to multiple power outlets on extension leads Do not rest hot or heavy objects on the appliance Always unplug the unit from the power outlet before cl...

Page 3: ...CONTENTS Introduction 3 Installation 5 Control panel 8 Operation 9 Description of remote control 10 Water drainage methods 14 Maintenance and service 15 Trouble shooting 16 Specifications 17 2...

Page 4: ...ss water and ensure the water tray only needs occasional emptying GUIDELINES FOR OPTIMISING COOLING EFFECTIVENESS Do not place the air conditioner or plastic window slider in direct sunlight Close all...

Page 5: ...the water tray tank 10 Power cable cord and plug 11 Air exhaust hose approx 1 5m long fully extended 12 Hose outlet connects in window slider 13 Hose inlet connects to air exhaust hose housing 14 Cas...

Page 6: ...inlet and outlet The hose inlet and outlet cannot be installed unless the hose ends have been fully extended Clip the hose outlet into the window slider Take care to not break the tabs on the hose ou...

Page 7: ...ry and keep the air exhaust hose horizontal and do not extend its length by attaching it to another hose as this reduces the cooling capacity of the appliance If the hose needs to be extended use as f...

Page 8: ...e awning window and sliding door Fig 11 and 12 8 0 1 g i F 9 g i F 2 1 g i F 1 1 g i F Window slider length Gaps can be sealed using cardboard or plastic and duct tape Window Door slider height Standa...

Page 9: ...om may not necessarily reach this set temperature If the appliance is turned off during cooling or dry dehumidifying operation and turned on again immediately the unit will wait at least 3 minutes bef...

Page 10: ...iances DEHUMIDIFYING DRY MODE for quieter operation In dehumidifying mode the appliance must have the exhaust hose fitted to allow air to be discharged externally The unit will not cool or dehumidify...

Page 11: ...ed of HIGH MED LOW AUTO 9 POWERFUL button 10 ON OFF button Press this button to switch on off the appliance 11 TIMER button Press this button to set automatic startup shutdown 12 SLEEP button Press th...

Page 12: ...ote control Insert two AAA 1 5V batteries in the correct position see instructions inside the battery compartment Replace the cover If the remote control is not used for long periods remove the batter...

Page 13: ...ed and it is not possible to set the temperature or change the fan speed This function is useful at night as it reduces the fan speed to low and dims the display on the unit To set this function corre...

Page 14: ...10 Turn on the appliance and set the working mode COOL or DRY you require when the appliance starts up from standby for example cooling mode 25 C fan speed high 13...

Page 15: ...cidental spillage when shifting the air conditioner to wheel the unit outside remove the drain plug and drain the water onto the ground The water tank is considered sufficiently drained when no more w...

Page 16: ...lter 2 Wash the filter by immersing it gently into warm water about 40 degrees celsius with a dishwashing detergent 3 Rinse the filter of detergent and dry it thoroughly in a shaded place 4 Insert the...

Page 17: ...nutes The compressor and fan has stopped Is Ft displayed on LCD Drain water Air Conditioner not cooling satisfactorily Cooling power not enough for the conditions of area or room Air exhaust hose bloc...

Page 18: ...Rated voltage 240 volts Rated power input 1200 watts Refrigerant R410a 500gm Cooling capacity 2 900 watts 10 000 BTU0 LIMIT CONDITIONS OF AIR CONDITIONING Room ambience in air conditioning Temperature...

Reviews: