Polocool HN 10C User Manual Download Page 15

14

12 

WATER DRAINAGE METHOD

This air conditioner is equipped with the very latest MIST technology which means that the water tank 
NEVER needs emptying even in high humidity areas. Water drainage will generally only be required at the 
end of the season (see End of Season Operations – page 15)
However, the mist technology does not operate when the unit is in dry (dehumidifying) mode. Thus, the tank 
may require emptying on occasions when operating for long periods in this mode.

NOTE
As a safety measure, to positively prevent water spillage, the air conditioner is equipped with a fail safe 
device, if, the water tank fills. The unit will completely stop, the control panel displays “ 

11 

”  (FULL 

TANK) as mentioned in SELF-DIAGNOSIS in page 17, the compressor and fan will not restart until  
the tank has been drained.

Before draining the water tank (tray) take care not to move the air conditioner as water may spill onto the floor.

Turn the air conditioner off using the on/off switch on the unit or remote control. Then drain the water tank by 
unplugging the drain outlet and allowing the water to flow onto the drain pan. The drain pan will not hold the 
full contents of the water tank. A number of fills of the drain pan are required. It may be easier (after 3 or 4 
pans have been drained in order to avoid accidental spillage when shifting the air conditioner) to wheel the 
unit outside, remove the drain plug and drain the water onto the ground.

The water tank is considered sufficiently drained when no more water flows from the drain outlet.

Restart the air conditioner by pressing the on/off button. Ensure that the unit is in COOL or DRY mode. The 
compressor will start approximately 3 minutes after the unit is switched on.

NOTE
To completely drain all water from the water tank, tilt the unit by lifting it slightly upwards from 
the front until no more water drains from the outlet.

CONTINUOUS DRAINAGE

When operating in dry (dehumidifying) mode continuous drainage can be used to avoid the trouble of manual 
drainage.

This appliance is equipped with a second drain outlet half way up the back of the unit for this purpose.

To operate the continuous drain method:

(1)  Empty the water tank completely

(2)   Connect one end of the drain hose on the middle drain outlet (pick 

the hose end that has a tight fit on this outlet) and lead the other end 
to outdoor or other place where it can drain freely. The bottom drain 
outlet can also be used but is not as effective as the middle drain 
outlet as this outlet puts a greater slope on the drain pipe which drains 
the water more quickly and makes the dry mode work more effectively

(3)  Turn on the appliance and select dry mode

When this continuous drainage method is adopted in dry mode, water 
removed from the air flows out through the drain hose continuously.

Summary of Contents for HN 10C

Page 1: ...igerated air conditioners are imported and distributed throughout Australasia by POLO Any enquiries should be directed to Polo on 1 800 087 840 in the first instance PORTABLE REFRIGERATED AIR CONDITIO...

Page 2: ...control panel or the remote control Do not connect to multiple power outlets on extension leads Do not rest hot or heavy objects on the appliance Always unplug the unit from the power outlet before cl...

Page 3: ...CONTENTS Introduction 3 Installation 5 Control panel 8 Operation 9 Description of remote control 10 Water drainage methods 14 Maintenance and service 15 Trouble shooting 16 Specifications 17 2...

Page 4: ...ss water and ensure the water tray only needs occasional emptying GUIDELINES FOR OPTIMISING COOLING EFFECTIVENESS Do not place the air conditioner or plastic window slider in direct sunlight Close all...

Page 5: ...the water tray tank 10 Power cable cord and plug 11 Air exhaust hose approx 1 5m long fully extended 12 Hose outlet connects in window slider 13 Hose inlet connects to air exhaust hose housing 14 Cas...

Page 6: ...inlet and outlet The hose inlet and outlet cannot be installed unless the hose ends have been fully extended Clip the hose outlet into the window slider Take care to not break the tabs on the hose ou...

Page 7: ...ry and keep the air exhaust hose horizontal and do not extend its length by attaching it to another hose as this reduces the cooling capacity of the appliance If the hose needs to be extended use as f...

Page 8: ...e awning window and sliding door Fig 11 and 12 8 0 1 g i F 9 g i F 2 1 g i F 1 1 g i F Window slider length Gaps can be sealed using cardboard or plastic and duct tape Window Door slider height Standa...

Page 9: ...om may not necessarily reach this set temperature If the appliance is turned off during cooling or dry dehumidifying operation and turned on again immediately the unit will wait at least 3 minutes bef...

Page 10: ...iances DEHUMIDIFYING DRY MODE for quieter operation In dehumidifying mode the appliance must have the exhaust hose fitted to allow air to be discharged externally The unit will not cool or dehumidify...

Page 11: ...ed of HIGH MED LOW AUTO 9 POWERFUL button 10 ON OFF button Press this button to switch on off the appliance 11 TIMER button Press this button to set automatic startup shutdown 12 SLEEP button Press th...

Page 12: ...ote control Insert two AAA 1 5V batteries in the correct position see instructions inside the battery compartment Replace the cover If the remote control is not used for long periods remove the batter...

Page 13: ...ed and it is not possible to set the temperature or change the fan speed This function is useful at night as it reduces the fan speed to low and dims the display on the unit To set this function corre...

Page 14: ...10 Turn on the appliance and set the working mode COOL or DRY you require when the appliance starts up from standby for example cooling mode 25 C fan speed high 13...

Page 15: ...cidental spillage when shifting the air conditioner to wheel the unit outside remove the drain plug and drain the water onto the ground The water tank is considered sufficiently drained when no more w...

Page 16: ...lter 2 Wash the filter by immersing it gently into warm water about 40 degrees celsius with a dishwashing detergent 3 Rinse the filter of detergent and dry it thoroughly in a shaded place 4 Insert the...

Page 17: ...nutes The compressor and fan has stopped Is Ft displayed on LCD Drain water Air Conditioner not cooling satisfactorily Cooling power not enough for the conditions of area or room Air exhaust hose bloc...

Page 18: ...Rated voltage 240 volts Rated power input 1200 watts Refrigerant R410a 500gm Cooling capacity 2 900 watts 10 000 BTU0 LIMIT CONDITIONS OF AIR CONDITIONING Room ambience in air conditioning Temperature...

Reviews: