background image

POLITEC s.r.l. | Manual Sandor HYBRID SMA – Ver. 1.2 

INDEX 

1  MAIN COMPONENTS 

Pag. 3 

2  MOUNTING SAMPLES 

Pag. 4 

MOUNTING WITH BRACKETS 

Pag. 5 

3  INSTALLATION SAMPLES 

Pag. 6 

4  WIRING 

Pag. 7 

5  CONFIGURATION OF THE OPTICALS 

Pag. 8 

OPTICAL TX 

Pag. 8 

OPTICAL RX 

Pag. 9 

6  SANDOR WS SMA TX MOTHER BOARD 

Pag. 10 

7  SANDOR WS SMA RX MOTHER BOARD 

Pag. 11 

8  SETTINGS & FUNCTIONS 

Pag. 12 

DIP SWITCHES 

Pag. 12 

9  COLOUMN ALIGNMENT 

Pag. 13 

10  CALIBRATION WITH SMA SYSTEM 

Pag. 14 

11  PARALLEL BEAMS CALIBRATION 

Pag. 18 

12  ALARM SENSITIVITY ADJUSTMENT 

Pag. 19 

13  TECHNICAL CHARACTERISTICS 

Pag. 20 

Installation recommendation 

Verify that the beam tower is fully watertight once the cover and end caps have been correctly filled at the
end of the installation.

Use the cable glands supplied on the tower for all cabling must pass through the lower end cap using the
cable  glands  supplied.  The  missed  used  of  proper  accessories  decrease  the  IP  grade  protection  of  the
tower.

Avoid any type of obstruction between the transmitter and receiver.

Avoid installing the receivers beams in a position where direct sunlight, at the same angle as the receivers
beams, can enter directly into optics especially at sunset and sunrise

Do  not  install  multiple  beams  where  the  transmitter  beam  can  interfere  with  other  receiver  beams.  It  is
always better place either transmitter or receivers back to back.

Summary of Contents for SANDOR HYBRID SMA

Page 1: ...Technical manual...

Page 2: ...ommendation Verify that the beam tower is fully watertight once the cover and end caps have been correctly filled at the end of the installation Use the cable glands supplied on the tower for all cabl...

Page 3: ...OMPONENTS N Description 1 Aluminium profile 2 IR cover 3 Caps 4 Opticals TX RX 5 Terminals card 6 Mother board 7 Battery 3 6 V 19 Ah 8 Wireless trasmitter position 9 Power supply 12Vdc 10 Thermostat b...

Page 4: ...POLITEC s r l Manual Sandor HYBRID SMA Ver 1 2 4 2 MOUNTING SAMPLES Pole mounting with SAN PL Wall mounting with SAN SD Wall mounting with SAN PL...

Page 5: ...SAN PL on the wall when you place the protection of gates windows doors along the wall to avoid small obstacles hinges edges of window sills that could create signal attenuation Insert the bracket on...

Page 6: ...C s r l Manual Sandor HYBRID SMA Ver 1 2 6 3 INSTALLATION SAMPLES Standard perimeter protection In the case of overlapped barriers RX TX4 TX3 TX2 TX1 TX RX TX RX4 RX3 RX2 RX1 RX4 RX3 RX2 RX1 TX4 TX3 T...

Page 7: ...POLITEC s r l Manual Sandor HYBRID SMA Ver 1 2 7 4 WIRING 220 Vac 12 Vdc THERMOSTAT BOARD POWER SUPPLY BOARD 3 6V MOTHERBOARD TX or RX...

Page 8: ...ITEC s r l Manual Sandor HYBRID SMA Ver 1 2 8 5 CONFIGURATION OF THE OPTICALS OPTICAL TX NB The address settings as per default 1 2 3 4 5 6 1 2 3 4 5 6 TX1 TX2 TX3 TX4 TX5 TX6 TEST LED TAMPER TEST BUT...

Page 9: ...POLITEC s r l Manual Sandor HYBRID SMA Ver 1 2 9 OPTICAL RX 1 2 3 4 5 6 1 2 3 4 5 6 RX1 RX2 RX3 RX4 RX5 RX6 NB The address settings as per default TAMPER LOW SIGNAL LED TEST LED TEST BUTTON...

Page 10: ...POLITEC s r l Manual Sandor HYBRID SMA Ver 1 2 10 6 SANDOR WS SMA TX MOTHER BOARD N B When the motherboard is supplied the LED ON will flash LED ON TAMPER BATTERY CONNECTION 3 6 V 19 Ah...

Page 11: ...THER BOARD N B When the motherboard is supplied by battery the TEST LED will flash LED TEST BATTERY CONNECTION 3 6 V 19 Ah 3 6 V 3 0 V TAMPER ALARM TAMPER SUPPLY INTERVENTION DELAY ADJUSTING BATTERY L...

Page 12: ...2 3 4 5 6 7 8 9 10 Ex Function AND 1 2 with 6 beams 10 DIP SWITCHES RX 1 AND At least 2 optical must be interrupted to give alarm 2 AND 1 2 AND function only for 1st and 2nd beam usefull in case of gr...

Page 13: ...negative open collector AN REMOTE CONTROL Giving a positive 3 6 V the AND function is activated AMK ANTIMASK Segnalazione di mascheramento data dalla chiusura al negativo di un open collector 9 COLOUM...

Page 14: ...e use of the supplied filter 1 Fold the device by following the folds preset 2 Place the filter in front of the optics TX positioning the two hooks on the pins of the fork optics to effectively search...

Page 15: ...the programming mode indicated by the flashing LED test During this phase the LED will continue to flash 4 Start the alignment of the barrier is on activating the transmitter optics TX TEST pressing...

Page 16: ...l alignment based on the BUZZER and LED high brightness of alignment the increase in the frequency of blinking of the LEDs and the whistle of the corresponding BUZZER indicate better ALIGNMENT 7 By a...

Page 17: ...put in OFF the DIP 10 on the motherboard to deactivate the programming mode indicated by the LED turns off For the next 30 seconds the barrier will sound continuously in case of alignment not effectiv...

Page 18: ...xplained Put TEST optics TX2 and RX2 and proceed with the calibration as previously explained Put TEST optics TX3 and RX3 and proceed with the calibration as previously explained Put TEST optics TX4 a...

Page 19: ...entiometer counterclockwise to increase the alarm delay up to 500ms In this condition ensures the alarm of a person walking through the barrier with the advantage of excluding the possibility of any f...

Page 20: ...ANDOM SETTABLE BEAMS EXCLUSION Yes ANTI CRAWLING FUNCTION FIRST BEAM LOW Yes COLUMN SUPPLY BATTERY 3 6 V 19 Ah OUTPUT Rel con contatti liberi NC NO su RX TAMPER OUTPUT Free contact relay NC NO on RX a...