POLITEC s.r.l. | Manual Sandor HYBRID SMA – Ver. 1.2
13
CONECTOR 8
1
HTR
Not utilized
2
3
ALLARME
NC Alarm relay
4
5
TAMPER
NC Tamper relay
6
7
SUPPLY
Possibility to supply the radio trasmitter with 3,0 or 3,6 V
8
CONNECTOR 4
BL
BATTERY LOW
Low battery indication (negative open collector)
SL
SIGNAL LOW
Fog disqualification (negative open collector)
AN
REMOTE
CONTROL
Giving a positive (3,6 V) the AND function is activated
AMK
ANTIMASK
Segnalazione di mascheramento data dalla chiusura al negativo di un
open collector.
9.
COLOUMN ALIGNMENT
For proper alignment once installed barriers orient optical groups of the transmitters and receivers each optical
groups in the direction of others. Adjusting horizontally through the manual movement, and vertically through
the front screws placed above the lenses.
Vertical adjustment
Horizontal adjustment