14
SADRIN WS SMA
POLITEC | INSTALLATION MANUAL - VER.2.1
10.Configuration
RX COLUMN
1
TEST In the ON position, the TEST phase for the barrier alignment is activated.
2
AND
In the ON position, an alarm event is recorded in the event of at least two beams
being obscured.
3
FAST
In the ON position, the intervention time is reduced, making the barrier itself more
sensitive.
TX COLUMN
1
TEST
In the ON position, the TEST phase for the barrier alignment is activated.
2
/
Not in use
11.Technical specifications
SADRIN WS
205
SADRIN WS
410
SADRIN WS
615
SADRIN WS
820
Outdoor range *
From 0.4 to 10 metres
(MAX. 3 metres for white version)
Synchronism
Optical
Double beam optic
SYSTEM with 15mm lenses in AND
Optical sensors
Pulsed type beams with a wavelength of 950 nm
Max. configuration
2TX+2RX
4TX+4RX
6TX+6RX
8TX+8RX
Beam arrangement
Parallel
Power supply
Lithium Batteries 3.6 Volt - 19 Ah WSE / 3.6 Volt - 2.7 Ah WSI
Consumption per column
0.30 mA
0.50 mA
0.65 mA
0.85 mA
Alarm Output
Relay with NC clean contacts (on RX column)
Anti-tampering output
Relay with NC clean contacts (on RX column)
tamper TX column opening optically transmitted on RX
Low battery output
Acoustic and O.C. signalling on RX column,
of the TX column optically transmitted on RX
Ingress protection rating
IP54/65 (on request)
Operating temperature
-10
°
C / +70
°
C
Profile dimensions WxDxH
25mm x 24mm from 500mm to 4000mm
Dimensions with caps WxD
29.5mm x 26.6
Box dimensions (WSE)
40mm x 39mm x 225mm (H to be added)
Usable space x TX (WSE)
35mm x 35mm x 100mm
Warranty