INSTALLATION AND WIRING MANUAL VERSION 1.8

1

Summary of Contents for ADEBUS

Page 1: ...PRODUCT ADEBUS GAPID EXPLORER ADEBUS GAPID EXPLORER Product code ADEBUS GAPID EXPLORER MONITORING CONTROL UNIT INSTALLATION AND WIRING MANUAL VERSION 1 8 1...

Page 2: ...ation method 15 11 Connection of sensors to the control unit 17 12 First access to the Adebus G board via IP address 192 168 1 222 18 13 Gapid Explorer installation 19 14 First start up 21 14 1 Main s...

Page 3: ...ports Com0 and Com1 Adebus Gapid manages supervises and configures every single Gapid SR or groups combined with Adebus hardware boards set up with the appropriate firmware reachable through a TCP IP...

Page 4: ...om the production date The warranty is applied to those purchasing directly from Politec there is no warranty for the end user who in the event of breakdowns or faults must contact the installer or de...

Page 5: ...Vac transformer 5 ALPO1B Power supply board 6 BATTERY not included 17 Ah Battery compartment 7 TAMPER 5 ADEBUS GAPID EXPLORER 4 1 The control unit The box contains the following components and accesso...

Page 6: ...3x20 5 Gapid SR container 6 Fixing plate 7 Cable glands 6 ADEBUS GAPID EXPLORER 4 2 Gapid SR The box contains the following components and accessories When opening the package check that everything h...

Page 7: ...put 3 24 Vac output 4 0 13 8 Vdc outputs 5 Battery output 6 10 A fuse 24 Vac 7 3 A fuse 12 Vac 8 3 A fuse battery 5 Board Description 7 ADEBUS GAPID EXPLORER 5 1 ALPO1B Power supply board POLITEC INST...

Page 8: ...line COM1 2 Serial input line COM2 3 0 12 Vdc input 4 LAN port 5 Relay outputs block 6 Inputs 7 Relay expansion connection 8 ADEBUS GAPID EXPLORER 5 2 ADEBUS G Adebus motherboard POLITEC INSTALLATION...

Page 9: ...Input connector from CA 230 motherboard 6 Input connector from previous expansion board 9 ADEBUS GAPID EXPLORER 5 3 ADEBUS ESP Expansion of 16 relay outputs for Adebus POLITEC INSTALLATION MANUAL VER...

Page 10: ...s advisable to proceed as follows a Place all the products with the package open on a table b Test the functioning of the sensors c Arrange without fixing the sensors in the planned points d Check tha...

Page 11: ...ate positioned on the other side Tighten the screws firmly to prevent the device from moving Fasten the cable with cable ties to the fence or support on which you have mounted the Gapid SR and wire th...

Page 12: ...Com2 for Com1 the ADEBUS S2 accessory is required On the other hand using a single serial port it is mandatory to create a single branch of the RS485 bus without making further branches In this case h...

Page 13: ...connections of the Relay outputs are divided into 4 groups for each expansion board and the common ones are as follows C1 4 common first 4 relays C5 8 common second 4 relays C9 12 common third 4 relay...

Page 14: ...ion to the previous Gapid or the Adebus control unit Output Connector Connection to the next Gapid Sensitivity adjustment trimmer It is generally used to check sensitivity in the field This sensitivit...

Page 15: ...o that the vibrations they will receive are the same for all sensors Begin mounting the first sensors of each serial branch starting from the beginning of the fencing N B For correct operation all sen...

Page 16: ...nels typical mounting in the centre of alternate panels i e one yes one no If vibrations are propagated considerably it is possible the to mount one every three panels i e one yes and two no Rigid wir...

Page 17: ...rol unit must be made exclusively with the serial cable input and output mode following the diagram below Ci A B Co A B If required make the same connection for COM2 Vdd Braid Braid R Ci A B Co A B Ci...

Page 18: ...S GAPID EXPLORER POLITEC INSTALLATION MANUAL VER 1 8 Connect the PC to the LAN connector of the ADEBUS G board with Ethernet cable The system is accessible via Gapid Explorer software or via the WEB N...

Page 19: ...d newer versions 13 1 Gapid Explorer Gapid Explorer is a supervision and configuration program for Gapid SR sensors The software can be used in three different languages English Italian French 13 2 Fi...

Page 20: ...he window is open with the left button of the mouse choose Internet Protocol and click Properties Choose if not already selected an IP address different from that of the ADEBUS G board default is 192...

Page 21: ...ctions the use of which is illustrated below Proceed in the order listed by the software 14 2 Working path It allows you to modify the work folder of the program where the database of events and sites...

Page 22: ...that represents the site map Select the site created via the drop down menu and activate the Configuration mode function Select Board Configuration and enter the name of the Adebus G board with its IP...

Page 23: ...e wiring between the last addressed sensor and the first unaddressed sensor and check the addressing again Select the board created select the COM1 COM2 serial port connected to the Gapid SR sensors a...

Page 24: ...have been created select the Groups function to associate the sensors Each Group must contain at least 4 sensors If some sensors are not associated with Groups these sensors will be considered complet...

Page 25: ...tion to configure a group Current configuration New configuration SENSITIVITY Sensitivity of the sensors within the group the higher it is the lower the pre alarm threshold of the individual sensors T...

Page 26: ...Outputs you can access the menu of the outputs relating to the Group The relay outputs of the Adebus are managed as follows N B The outputs are by default in active safety It is possible to invert all...

Page 27: ...e alarm of a single sensor has been triggered the concentrator will carry out checks along the whole line of the group to confirm the alarm MODE It is the type of sensor programming according to the a...

Page 28: ...u you access the algorithm thresholds and the configuration of the inputs Click on Copy and Send to apply the standard configuration of the algorithms Activate the Input 1 enable recording flag so tha...

Page 29: ...ent colours in the case of recorded events such as Alarm Tamper Offline Disabled These events will also be associated with Pop Ups if enabled By double clicking on the Group or on the single sensor if...

Page 30: ...iguration via WEB it is necessary to enable using the appropriate button Enable config WEB This function is normally disabled to keep the system safety level high Through the WEB management it is poss...

Page 31: ...case of loss of communication on a single sensor the whole group goes OFFLINE High BadCom Day In the event that a sensor loses several packets within 24h but not communication an alert is given This f...

Page 32: ...sswordsThe standard user can only view the system status and cannot modify outputs configurations 17 1 Enable pop up The system allows to use PopUps in case of important system events During the group...

Page 33: ...le to reset the Adebus G board to the factory settings by performing this procedure Disconnect the Adebus G board Remove the COM1 serial port module Make a jumper on contact 3 5 Power up and wait for...

Page 34: ...here is the detail of the address of the first and last sensor in the group The Online and Local structures must be identical if a sensor has been inserted or removed from the group the Structure must...

Page 35: ...d Pulse Counter Vibration threshold for pre alarm of each sensor Pulse Time Vibration reset time Event Time Minimum reading time between one vibration and the next X value Algorithmic value of group a...

Page 36: ...an the group one this configuration will not be overwritten unless the highlighted flags are deselected E g Gapid SR 1 and Gapid SR 6 have a different configuration than the group for example less sen...

Page 37: ...this function the TEST function must also be activated With this function it is possible to record the spontaneous vibration of the fence on a single sensor To register it it is necessary a single hit...

Page 38: ...on it is possible to record a particular vibration of the fence on a single sensor To register it it is necessary a single hit to the fence and verify its registration by viewing the status of the sin...

Page 39: ...y a single hit to the fence and verify its registration by viewing the status of the single sensor The Self acq by disqualification registered flag indicates that the sensor has registered this type o...

Page 40: ...em retains the number of peak vibrations of each sensor for 30s by default Close Gapid SR percentage The system generates a Group alarm if the sensors adjacent to the alarmed sensor have registered a...

Page 41: ...ocedure Disconnect from the site Modify the desired segments groups via Configuration Mode Connect to the site Click the SEND GROUP STRUCTURE button If necessary modify the programming sensitivity out...

Page 42: ...us ADDRESSING Automatic TECHNICAL SIGNALS OUTPUT Deactivation Off line OUTPUTS Alarm Directly on serial Tamper Directly on serial Dimensions WxHxD 98 x 66 x 25 5mm MATERIAL Anti scratch UV resistant b...

Page 43: ...IAL PORTS 2 RS485 including 1 optional SERIAL BUS LINE LENGTH 750m for each line with indicated cable EVENT STORAGE CAPACITY 32000 exportable COMMUNICATION OUTPUT LAN LIVE VIEWING Status of each senso...

Page 44: ...able recycling or disposal systems for this category of products governed by regulations in force in your area Warning Some parts of the products may contain polluting or dangerous substances which if...