6
V. Installation
The feeder should be installed before the controller.
A. Feeding System
Install the feeding system as shown in Figure 3 or in accor-
dance with the installation instructions that were provided with
the feeder.
B. Controller Installation
The voltage on the feeder solenoid valve must match the output
voltage of the controller. The C316 Controller must be matched
with a 24V solenoid valve.
1.
Turn off the power to the filter pump at the breaker box.
2.
Remove the Caution Plate at the bottom of the controller by
removing the two screws.
3.
To avoid damage, remove the controller module from the
controller box by removing the BNC connector(s) and the
faceplate screws.
4.
Drill or cut out the electrical access holes that are best
suited for your installation (using a hammer can damage the
controller). Install seal-tight or strain relief connectors in the
access holes and replace the module.
5.
Mount the controller on a wall or surface within eight feet of
the feeder.
316
Controller
110V to 24V Plug-in
Transformer
To Pool
Heater
pH Sensor
Filter
Pump
From Pool
Flow
Flow
Switch
Flow Cell
Check
Valve
24V Solenoid
Valve
Figure 3