5
B. Switch Settings
1.
Dip switches #1 and #2 control the feed times. Feed times
vary depending on whether the controller is in the pool or
spa mode.
Note: Once the settings have been modified, move the
Pool/Spa Switch on the front of the controller to the appro-
priate mode to activate the changes. Refer to Figure 4.
2.
Dip switch #3 controls the delay time between feeds.
OFF
30 sec.
ON
7 min.
3.
Dip switch #4 must be in the OFF position.
4.
Dip switch #5 controls the low ORP shutoff.
The controller is set to shut down when the ORP level drops
below 100 mV. This prevents overfeeding if there is an ORP
sensor failure.
Moving switch #5 to the OFF position will override this
function. This override might be required in extremely small
bodies of water where sudden organic loads dissipate the
sanitizer in a very short time.
5.
Dip switch #6 has no assigned function.
Pool Position
Dip Switch
Feed
1
2
Time
OFF
ON
1 min.
ON
ON
5 min.
OFF
OFF
10 min.
Spa Position
Dip Switch
Feed
1
2
Time
OFF
OFF
1 sec.
ON
OFF
5 sec.
OFF
ON
10 sec.