PDM FUSE
“DOWNSTREAM” FUSES
START (15A)
FUEL (10A)
If you believe a PDM fuse may be causing intermittent power to its “downstream”
fuses, follow the procedure for replacing and testing below.
1. Place the vehicle in PARK, turn off the engine, and then turn the ignition
switch to the ON position.
2. Access the Primary Fuse Center in the driver-side rear wheel well.
3. Gently nudge the suspected PDM fuse by hand and check to see if
intermittent power occurs to vehicle functions. This will simulate vehicle
operation and help confirm which PDM is at issue. If intermittent power does
not occur, perform the same nudge test on the remaining PDM fuses.
4. Once the correct PDM fuse is confirmed, turn the ignition switch to the OFF
position.
5. Replace the PDM fuse using one of the SPARE fuses.
IMPORTANT
After removing a fuse, always check to ensure the two wire terminals that the
fuse connects to are properly seated. Dislodged or misaligned wiring may also
cause intermittent power to vehicle functions. If this is the case, adjust the
wires by pushing up from the backside of the fuse block. If the problem
persists, consult your dealer.
6. Turn the ignition switch to the ON position.
7. Gently nudge the SPARE fuse and check to see if intermittent power occurs
to vehicle functions.
If power to vehicle functions appears consistent, the vehicle may resume
operation. It is recommended that the vehicle be seen by a dealer for further
assessment.
If power to vehicle functions remains inconsistent, do not operate the vehicle.
Have the vehicle brought to a dealer immediately.
107
Summary of Contents for RZR Pro R 2022
Page 1: ...OWNER S MANUAL For Maintenance and Safety 2022 RZR Pro R...
Page 3: ...Owner s Manual RZR Pro R...
Page 8: ...6...
Page 84: ...82...
Page 124: ...FOX SHOCKS IF EQUIPPED SHOCK LOCATION MEASUREMENT Front Shock Rear Shock 122 MAINTENANCE...
Page 150: ...TIE DOWN LOCATIONS q Front tie down point w Rear tie down points 148 MAINTENANCE...
Page 178: ...176...
Page 190: ...188...
Page 194: ......