69
TROUBLESHOOTING
Troubleshooting Symptoms
No Power at DC Receptacle
POSSIBLE LEAN
FUEL CAUSE
SOLUTION
Low or contaminated fuel
Add fuel or drain the fuel system and refuel
Kinked or plugged fuel tank
vent
Inspect and replace
Low octane fuel
Drain the fuel system and refuel
Carburetor jetting incorrect Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
POSSIBLE RICH
FUEL CAUSE
SOLUTION
Incorrect fuel / fuel is very
high octane
Drain the fuel system and refuel
Stopping / starting without
adequate warm-up
Allow the engine to warm up before operating and / or
stopping
Incorrect spark plug
Inspect and replace with correct spark plug
Clogged air cleaner filter
Inspect and clean or replace
POSSIBLE CAUSE
SOLUTION
DC circuit protector blown
Replace the fuse
Faulty generator
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual