
68
TROUBLESHOOTING
Troubleshooting Symptoms
Engine Pings or Knocks
Engine Runs Irregularly, Stalls, or Misfires
POSSIBLE CAUSE
SOLUTION
Poor quality or low octane
fuel
Replace with recommended fuel
Incorrect ignition timing
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Incorrect spark plug gap or
heat range
Set gap to specification or replace spark plug
POSSIBLE CAUSE
SOLUTION
Fouled or defective spark
plug
Inspect, clean, and / or replace spark plug
Worn or defective spark
plug
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Incorrect spark plug gap or
heat range
Set gap to specification or replace spark plug
Loose ignition connections Check all connections and tighten
Water present in fuel
Drain the fuel system and refuel
Kinked or plugged fuel tank
vent line
Inspect and replace
Incorrect fuel
Drain the fuel system and refuel
SMART throttle control
malfunction
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Mechanical failure
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Summary of Contents for Power P1000i
Page 80: ...PMS 419 ...