DC Inverter Monoblock Duct Type Air Conditioner Installation and Operation Manual
14
(2) First select an installation position. According to the size of the control wire of the wire
controller, leave a recess or a embedded wire hole to bury the control wire.
(3) If the control wire between the wire controller and the indoor unit is surface-mounted, use
1# metallic pipe and make matching recess in the wall (refer to Fig.16; If concealed installation is
adopted, 1# metallic pipe can be used (Refer to Fig.17).
(4) No matter if surface mounting or concealed mounting is selected, it is required to drill 2 holes
(in the same level) which distance shall be the same as the distance (60mm) of installation holes in
the bottom plate of the wire controller. Then insert a wood plug into each hole. Fix the bottom plate
of the wire controller to the wall by using the two holes. Plug the control wire onto the control panel.
Lastly install the panel of the wire controller.
Caution:
During the installation of the bottom plate of the wire controller, pay attention to the direction of the
bottom plate. The plate’s side with two notches must be at the lower position, and otherwise the
panel of the wire controller cannot be correctly installed.
Fig.16 Surface mounting of Cable
Fig.17 Concealed mounting of Cable
Cautions:
①
The communication distance between the main board and the wire controller is 8 meters.
②
The wire controller shall not be installed in a place where there is water drop or large amount
of water vapor.