3
Routine Maintenance
Condenser Cleaning
The condenser is part of the refrigeration system. The condenser requires monthly cleaning.
Always disconnect power supply before carrying out Routine Maintenance.
Failure to clean the condenser will reduce the performance and life of your Polar unit and may
invalidate your warranty
The condenser is located behind the service door on the right-hand side of the refrigeration
cabinet. These models have a removable filter which can be cleaned with a vacuum cleaner.
Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR retailer.
Technical Specifications
Fault
Probable Cause
Action
The appliance is not working The unit is not switched on
Check the unit is plugged in correctly and switched on
Plug and lead are damaged
Call POLAR agent or qualified Technician
Fuse in the plug has blown
Replace the fuse
Power supply
Check power supply
Internal wiring fault
Call POLAR agent or qualified Technician
The appliance turns on, but
the temperature is too high/
low
Too much ice on the evaporator
Defrost the appliance
Condenser blocked with dust
Clean condenser with the hose attachement of a vacuum
Doors are not shut properly
Check doors are shut and seals are not damaged
Appliance is located near a heat source or air
flow to the condenser is being interrupted
Move the refrigerator to a more suitable location
Ambient temperature is too high
Increase ventilation or move appliance to a cooler position
Unsuitable foodstuffs are being stored in the
appliance
Remove any excessive hot foodstuffs or blockages to the fan
Appliance is overloaded
Reduce the amount of food stored in the appliance
The appliance is leaking
water
The appliance is not properly levelled
Adjust the screw feet to level the appliance (if applicable)
The discharge outlet is blocked
Clear the discharge outlet
Movement of water to the drain is obstructed Clear the floor of the appliance (if applicable)
The water container is damaged
Call POLAR agent or qualified Technician
The drip tray is full
Empty the drip tray (if applicable)
The appliance is unusually
loud
Loose nut/screw
Check and tighten all nuts and screws
The appliance has not been installed in a
level or stable position
Check installation position and change if necessary
Model
Voltage
Power
Current
Temperature
Range
Capacity
(litres)
Refrigerant
Dimensions
H x W x D (mm)
Weight
(Kg)
G596-A
220-240V 50Hz
350W
1.95A
-2°C to 10°C
282
R134a 230g
850 x 1360 x 700
98
G597-A
220-240V 50Hz
350W
1.95A
-2°C to 10°C
417
R134a 230g
850 x 1790 x 700
134
G598-A
220-240V 50Hz
350W
1.95A
-2°C to 10°C
563
R134a 250g
850 x 2230 x 700
153
G599-A
220-240V 50Hz
750W
3.5A
-10°C to -20°C
282
R404a 300g
850 x 1360 x 700
98
G600-A
220-240V 50Hz
750W
3.55A
-10°C to 20°C
417
R404a 300g
850 x 1790 x 700
136
U636-A
220-240V 50Hz
230W
1.5A
-2°C to 10°C
240
R134a 165g
880 x 900 x 700
72
G622-A
220-240V 50Hz
230W
1.6A
2°C to 10°C
368
R134a 260g
850 x 1365 x 700
110