background image

3

AU

AU

Telephone Helpline: 1300225960

•  Polar recommends that this appliance should be periodically 

tested (at least annually) by a Competent Person. Testing 

should include, but not be limited to: Visual Inspection, 

Polarity Test, Earth Continuity (Class I equipment), Insulation 

Continuity and Functional Test.

Caution Risk of Fire

•  Do not store explosive substances such as aerosol cans with a 

flammable propellant in this appliance.

Warning: Keep all ventilation openings clear of 

obstruction. Unit should not be boxed in without 

adequate ventilation.

•  Warning: Do not use mechanical devices or other means 

to accelerate the defrosting process, other than those 

recommended by the manufacturer.

•  Warning: Do not damage the refrigerant circuit.

•  Warning: Do not use electrical appliances inside the food 

storage compartments of the appliance, unless they are the 

type recommended by the manufacturer.

Product Description

CM530-A - POLAR 385 litre Chest Freezer 

 

CM532-A - POLAR 587 litre Chest Freezer

CM531-A - POLAR 516 litre Chest Freezer

Introduction

Please take a few moments to carefully read through this manual. Correct maintenance and operation of 

this machine will provide the best possible performance from your POLAR product.

Pack Contents

The following is included:

Polar 

Chest 

Freezer 

    Instruction 

manual

POLAR prides itself on quality and service, ensuring that at the time of packaging the contents are 

supplied fully functional and free of damage.

Should you find any damage as a result of transit, please contact your POLAR dealer immediately.

Installation

Note: If the unit has not been stored or moved in an upright position, let it stand 

upright for approximately 12 hours before operation. If in doubt allow to stand.

CM530-A_CM531-A_CM532-A_A5_v1_20190626.indb   3

2019/6/26   14:55

Summary of Contents for CM530-A

Page 1: ...Model CM530 A CM531 A CM532 A Chest Freezer Instruction manual CM530 A_CM531 A_CM532 A_A5_v1_20190626 indb 1 2019 6 26 14 55 ...

Page 2: ...ct with the plastic components or door seal Clean immediately if contact occurs Always carry store and handle the appliance in a vertical position and move by holding the base of the appliance Always switch off and disconnect the power supply to the unit before cleaning Keep all packaging away from children Dispose of the packaging in accordance with the regulations of local authorities If the pow...

Page 3: ...d storage compartments of the appliance unless they are the type recommended by the manufacturer Product Description CM530 A POLAR 385 litre Chest Freezer CM532 A POLAR 587 litre Chest Freezer CM531 A POLAR 516 litre Chest Freezer Introduction Please take a few moments to carefully read through this manual Correct maintenance and operation of this machine will provide the best possible performance...

Page 4: ...ith feet by default However castors can be supplied as an option Castors can be ordered using the code of AJ450 To replace with the castors follow below steps 1 Remove the feet support 2 Attach the castor support 3 Fix the castor support in place with screws 4 Mount the castor Operation Control Panel RUN indicator Temperature Display Thermostat Storing Food To get the best results from your POLAR ...

Page 5: ...LAR dealer Fault Probable Cause Solution The appliance is not working The unit is not switched on Check the unit is plugged in correctly and switched on Plug and lead are damaged Call POLAR agent or qualified Technician Fuse in the plug has blown Replace the fuse Power supply Check power supply Internal wiring fault Call POLAR agent or qualified Technician The appliance turns on but the temperatur...

Page 6: ...e readily accessible Compliance The product must not be disposed of as household waste To help prevent possible harm to human health and or the environment the product must be disposed of in an approved and environmentally safe recycling process For further information on how to dispose of this product correctly contact the product supplier or the local authority responsible for waste disposal in ...

Page 7: ...010 A1 2013 IEC 60335 2 89 2010 A1 2012 EN 62233 2008 BS EN 55014 1 2017 BS EN 55014 2 2015 BS EN 61000 3 2 2014 BS EN 61000 3 3 2013 Polar 15 Badgally Road Campbelltown NSW 2560 I the undersigned hereby declare that the equipment specified above conforms to the above Legislation and Standard s Date 6th March 2019 Signature Full Name Ashley Hooper Position Technical Quality Manager Responsible Sup...

Page 8: ...CM530 A_CM531 A_CM532 A_A5_v1_20190626 http www polar refrigerator com CM530 A_CM531 A_CM532 A_A5_v1_20190626 indb 8 2019 6 26 14 55 ...

Reviews: