Technical Specifications

Electrical Wiring

POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard. 
The plug is to be connected to a suitable mains socket. 
POLAR appliances are wired as follows:
•  Live wire (coloured brown) to terminal marked L
•  Neutral wire (coloured blue) to terminal marked N
•  Earth wire (coloured green/yellow) to terminal marked E 
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must 
be readily accessible.

Disposal

EU regulations require refrigeration product to be disposed of by specialist companies who remove or recycle all gasses, metal and 
plastic components.
Consult your local waste collection authority regarding disposal of your appliance. Local authorities are not obliged to dispose of 
commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally.
Alternatively call the POLAR helpline for details of national disposal companies within the EU.

Compliance

The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household 
waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in 
an approved and environmentally safe recycling process. For further information on how to dispose of this product 
correctly, contact the product supplier, or the local authority responsible for waste disposal in your area. 
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications 
set by international, independent, and federal authorities. 
POLAR products have been approved to carry the following symbol: 

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, 

recording or otherwise, without the prior written permission of POLAR.

Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to change specifications without 

notice.

The appliance is leaking 
water

The appliance is not properly levelled

Adjust the screw feet to level the appliance (if applicable)

The discharge outlet is blocked

Clear the discharge outlet 

Movement of water to the drain is 
obstructed

Clear the floor of the appliance (if applicable)

The water container is damaged

Call POLAR agent or qualified Technician

The drip tray is full

Empty the drip tray (if applicable)

The appliance is 
unusually loud

Loose nut/screw

Check and tighten all nuts and screws

The appliance has not been installed in a 
level or stable position

Check installation position and change if necessary

Model

Voltage

Power

Current

Temp

Range

Capacity

(litres)

Refrigerant

Dimensions

H x W x D (mm)

Weight 

(Kg)

Climatic 

Class

CE210

230V 50Hz 

230W

1.5A

-25 to -18C

392

R134a 210g

852 x 1331 x 701

63

4

CE211

230V 50Hz

230W

1.5A

-25 to -18C

464

R134a 210g

830 x 1483 x 1603

66

4

CE212

230V 50Hz

230W

2.3A

-25 to -18C

536

R134a 210g

934 x 1603 x 733

85

4

Summary of Contents for CE210

Page 1: ...Tiefkühltische Bedienungsanleitung Congelatori Manuale di istruzioni Congeladores Manual de instrucciones Congeladores Manual de instruções IT DE FR NL ES PT Model Modèle Modell Modello Modelo Malli CE210 CE211 CE212 Chest Freezer Instruction manual ...

Page 2: ...ded qualified technician in order to avoid a hazard Product Description CE210 POLAR 392 litre Chest Freezer CE211 POLAR 464 litre Chest Freezer CE212 POLAR 536 litre Chest Freezer Introduction Please take a few moments to carefully read through this manual Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product Pack Contents The followin...

Page 3: ...ician must carry out repairs if required Cleaning the Condenser Periodically cleaning the condenser can extend the life of the appliance Troubleshooting If your POLAR appliance develops a fault please check the following table before making a call to the Helpline or your POLAR retailer Fault Probable Cause Action The appliance is not working The unit is not switched on Check the unit is plugged in...

Page 4: ...her information on how to dispose of this product correctly contact the product supplier or the local authority responsible for waste disposal in your area POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities POLAR products have been approved to carry the following symbol All right...

Page 5: ... above conforms to the above Directive s and Standard s Ik de ondergetekende verklaar hierbij dat de hierboven gespecificeerde uitrusting goedgekeurd is volgens de bovenstaande Richtlijn en en Standaard en Je soussigné confirme la conformité de l équipement cité dans la présente à la aux Directive s et Norme s ci dessus Ich der die Unterzeichnende erkläre hiermit dass das oben angegebene Gerät der...

Page 6: ......

Page 7: ......

Page 8: ...CE210 2_UK_A5_v1 ...

Reviews: