4
Telephone Helpline
: 0845 146 2887 (United Kingdom)
Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.
Technical Specifications
Electrical Wiring
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Fault
Probable Cause
Action
The appliance is not
working
The unit is not switched on
Check the unit is plugged in correctly and switched on
Plug and lead are damaged
Call POLAR agent or qualified Technician
Fuse in the plug has blown
Replace the fuse
Power supply
Check power supply
Internal wiring fault
Call POLAR agent or qualified Technician
The appliance turns on, but
the temperature is too
high/low
Too much ice on the evaporator
Defrost the appliance
Condenser blocked with dust
Call POLAR agent or qualified Technician
Doors are not shut properly
Check doors are shut and seals are not damaged
Appliance is located near a heat source or air flow to the
condenser is being interrupted
Move the refrigerator to a more suitable location
Ambient temperature is too high
Increase ventilation or move appliance to a cooler position
Unsuitable foodstuffs are being stored in the appliance
Remove any excessive hot foodstuffs or blockages to the fan
Appliance is overloaded
Reduce the amount of food stored in the appliance
The appliance is leaking
water
The appliance is not properly levelled
Adjust the screw feet to level the appliance (if applicable)
The discharge outlet is blocked
Clear the discharge outlet
Movement of water to the drain is obstructed
Clear the floor of the appliance (if applicable)
The water container is damaged
Call POLAR agent or qualified Technician
The drip tray is overflowing
Empty the drip tray (if applicable)
The appliance is unusually
loud
Loose nut/screw
Check and tighten all nuts and screws
The appliance has not been installed in a level or stable
position
Check installation position and change if necessary
Model
Voltage
Power
Current
Temperature
Range
Capacity
Refrigerant
Dimensions
H x W x D (mm)
Weight
(kg)
G608
230V 50Hz
150W
1A
2°C toT 8°C
5 x gastronorm 1/4 Container
R600a 40g
435 x 1200 x 380
49
G609
230V 50Hz
150W
1A
2°C toT 8°C
7 x gastronorm 1/4 Container
R600a 40g
435 x 1500 x 380
57
G610
230V 50Hz
150W
1A
2°C toT 8°C
8 x gastronorm 1/4 Container
R600a 40g
435 x 1800 x 380
65
G611
230V 50Hz
230W
1,6A
2°C toT 8°C
10 x gastronorm 1/4 Container
R600a 40g
435 x 2000 x 380
34
GD875
230V 50Hz
150W
1A
2°C toT 8°C
3 x gastronorm 1/3 Container
1 x gastronorm 1/2 Container
R600a 40g
435 x 1200 x 380
28
GD876
230V 50Hz
150W
1A
2°C toT 8°C
5 x gastronorm 1/3 Container
1 x gastronorm 1/2 Container
R600a 40g
435 x 1500 x 380
31
GD877
230V 50Hz
150W
1A
2°C toT 8°C
8 x gastronorm 1/3 Container
R600a 40g
435 x 1800 x 380
35
GD878
230V 50Hz
230W
1,6A
2°C toT 8°C
9 x gastronorm 1/3 Container
R600a 40g
435 x 2000 x 380
37