background image

Sistem de alarma wireless 

PNI Safe House PG300

Manual de utilizare

Summary of Contents for Safe House PG300

Page 1: ...Sistem de alarma wireless PNI Safe House PG300 Manual de utilizare...

Page 2: ...dispecerat O iesire de tip releu NO NC 6 numere de telefon pentru apelare si 3 numere pentru SMS in cazul unui eveniment Armare dezarmare intercom si monitorizare sistem de la distanta Programare indi...

Page 3: ...tuati conexiunile in functie de tipul detectorului utilizat 4 Pentru setarile zonelor din aplicatia dedicata zona 1 cablata corespunde zonei 97 din aplicatie zona 2 cablata corespunde zonei 98 din apl...

Page 4: ...30xxxx xxxx parola noua formata din 4 cifre SMS schimbare parola programare 888831xxxx xxxx parola noua formata din 4 cifre Exemplu pentru a schimba parola de programare din 8888 in 0000 trimiteti com...

Page 5: ...ea pentru a trimite un semnal catre unitatea de comanda Aceasta va prelua semnalul si va con rma programarea telecomenzii prin mesajul vocal coding completed Pentru a mai programa inca o telecomanda a...

Page 6: ...re tineti cont ca acestia nu sunt imuni la animale asa ca daca armati sistemul indepartati animalele din zona protejata Stergere detectori Cand sistemul este dezarmat apasati scurt butonul SET unitate...

Page 7: ...ntru a inregistra vocal adresa alarmei apoi rostiti adresa spre unitatea de comanda Inregistrarea dureaza 10 sec Dupa nalizarea inregistrarii unitatea o va reda in difuzorul incorporat parola programa...

Page 8: ...atie sau trimiteti un SMS ce contine parola programare 45 timp intarziere 001 180 sec Exemplu pentru a seta o intarziere alarma de 80 sec trimiteti mesajul 888845080 Setare timp activare sirena Pentru...

Page 9: ...tru a seta data 26 08 2016 ora 16 00 00 trimiteti mesajul 88883220160826160000 Armare dezarmare automata Sistemul va permite programarea a 3 armari si 3 dezarmari automate Programare armare automata a...

Page 10: ...alarma pentru a trimite un semnal ce va receptionat de sirena ce va con rma printr un sunet scurt Operare programare sistem prin apel telefonic Toate setarile de mai sus pot efectuate si print un ape...

Page 11: ...cifra 1 de la tastatura Revenire la setarile din fabrica a Pentru a reseta sistemul de alarma la setarile din fabrica dezactivati bateri de rezerva apoi deconectati alimentarea principala a sistemului...

Page 12: ...reless nu suna veri cati daca sirena este alimentata Nu exista semnal GSM veri cati cartela SIM sa e introdusa corect veri cati cartela SIM sa nu necesite PIN veri cati daca unitatea de comanda functi...

Page 13: ...12 12 Wireless alarm system PNI Safe House PG300 User manual...

Page 14: ...urity dispatch One NO NC relay output 6 phone numbers for voice warnings and 3 for SMS Remote arm disarm intercom and monitor Individual programing for each zone Built in backup battery Support wirele...

Page 15: ...se or normally open The users can connect the wire according the wireless detectors or as own requirement 4 Attributes setting of APP wireless defense zones the wired zone 1 is corresponded to the def...

Page 16: ...rd SMS for changing the programming password 888831xxxx xxxx new 4 digit password For example to change the programming password from 8888 to 0000 send the SMS command 8888310000 ATTENTION If you chan...

Page 17: ...ir the second remote controller right now Caution The host can pair at most 8 remote controllers The method of pairing other remote controls is the same NOTE If no button is pressed for 30 sec the sys...

Page 18: ...button lightly again then the second blue LED light will be on the voice prompts detector coding Then long press SET button right now all the detectors in the defense zone 2 will be deleted The metho...

Page 19: ...1 Alarm mode 1 real time 2 delay default delay is 40 sec 3 24 hours 4 bypass Zone type 1 SOS 2 re 3 gas 4 door 5 hall 6 window 7 balcony 8 bypass Siren 0 activate siren on alarm 1 do not activate sire...

Page 20: ...option or send SMS programming password 77 0 1 0 disable function 1 you will receive a SMS every time you arm or disarm the alarm system Enable disable key sound not available for this model SMS warn...

Page 21: ...de number 4 digits The default encode number is 0000 Enlist wireless siren the alarm system can only command the enlisted sirens To enlist a wireless siren in the alarm system set the siren in program...

Page 22: ...tory default settings To reset settings to factory default turn off the backup battery then remove unit power Press and hold SET button while connecting the power All LEDs will turn on you will hear t...

Page 23: ...MS arm send SMS operation password 2 App arm EN System home arm Remote control home arm NOTE this function is only available if you enabled it in programming App home arm SOS alarm in this case of ala...

Page 24: ...ouldn t check if the main unit is on backup battery and if this is not charged check the GSM signal in the area with a phone Phone programming does not work check GSM signal try another SIM card try w...

Reviews: