1
6
Test
Maintenance
Emergency alarm treatment
LED information
To test the installed detector while using independently or in network, you
can give some gas around in distance of 5 cm to the gas convection holes by
using un-ignition lighter.Testing frequently may result in reducing the
sensitivity of the detector.The Detector will stop alarm and resume to the
detecting state while the gas density reduced to lower than the alarm
level.
Suggestion: the user must brush and clean the gas convection holes with a
little cleanser every three months, and must retest the detector after
cleaning for preventing the cleanser into the detector.
The detector alarms while the gas density in air exceed the alarm level. The
relative treatments as below:
1. Shut down the tube valve right away.
2. Open the window and make the air flow rapidly.
3. Extinguish all fire sources and do not use anything can make fire, e.g.
lighters, matches, etc.
4. Avoiding open or close the power all kinds of electric equipment.
5. Check the reason of gas leaking, and notice the relative departments and
professional persons in time.
RED LED FLASH
GAS LEAKING
RED LED ON
SENSOR FAILURE
GREEN LED Flash/ 0.5S on
WARM-UP SENSOR
Notice
1. The detector must be installed and connected correctly. It can not work if
without the power supply orderly.
2. Please periodically maintenance according to the directions.
3. The detector must have a test every half a year.
4.For various reasons, including, but not limited to, changes in
environmental conditions, electric or electronic disruptions and tampering,
the Product may not perform as expected. The user is advised to take all
necessary precautions for his/her safety and the protection of his/her
property.
EN