Pneumax
CAFS "DS" Series Installation Guide
Page 22 of 40
Observed Symptom
Probable cause
Suggested fix
Foam in the water system
(when proportioner turned off)
Foam concentrate was
poured into the on-board
water tank
Foam manifold drain lines not
isolated from water drain lines
Cooler line plumbed from
foam manifold
Foam manifold check valve
defective
Flush tank and pump with clean water,
refill
Isolate to separate drain valve
Relocate line to discharge side of
pump
Rebuild/replace check valve
Water in compressor oil/air
Leaking inside cooler
Freeze damage
Defective air check valves
Missing air check valves for
discharges
Isolate cooler and check for leaks,
replace if needed, check drain
Replace or check
Install check valves
Safety pop off valve opening
at low pressure
Auto Sync system out of
balance
Sump fire damaged pop off
valve
Adjust the Auto Sync system, making
sure to not open the trim valve on the
compressor more than 3 turns.
Check system for other damage and
replace valve
Safety pop off valve
repeatedly opening
Trim valve or inlet completely
open
Refer to trim valve (Auto Sync)
instructions
Summary of Contents for 120-60-DS
Page 30: ...CAFS DS Series Installation Guide Page 30 of 40 Modules 120 60 DS Top Side Front...
Page 32: ...CAFS DS Series Installation Guide Page 32 of 40 250 120 DS...
Page 36: ...CAFS DS Series Installation Guide Page 36 of 40 120 60 Hydraulic Flow...
Page 37: ...CAFS DS Series Installation Guide Page 37 of 40 Auto Sync Wiring Schematic electric...
Page 38: ...CAFS DS Series Installation Guide Page 38 of 40 Auto Sync Air Schematic electric...
Page 39: ...CAFS DS Series Installation Guide Page 39 of 40 Auto Sync Air Schematic manual...