P a g e
4 | 8
Plumbing
PMP-
04 “The Prodigy”
The Prodigy pump has inlet and outlet on opposing sides of the pump.
Inlet side is the 1.5” tri
-clamp
connection closet to the end of the pump (furthest from the motor). The outlet of the pump is on the
opposite side (closest to the motor).
Make connections using standard 1.5” Tri
-clamp style seals and clamps. Make sure seals and clamps are
rated for both pressure and solvents intended for use with your system. For LPG gas Viton or PTFE
gaskets are recommended, and clamps with a minimum rating of 250psi.
Tighten clamps using proper torque recommendation by clamp manufacture. Be sure not to over
torque the clamps as this may cause damage.
Inlet
Outlet