background image

Page 7

Clean or replace pads as follows:

1. Disconnect power from unit.
2. Remove pads from cabinet as follows:
  a. Remove back panel from cabinet.
  b. Remove pads by sliding the pad straight backwards. 
3. If passages are clogged or pad is dirty, hose off inlet 

face of pad. Light, gentle brushing of the inlet edges 
of the pad with a stiff bristle brush (do not use a wire 
brush) will not harm the pad and will remove more 
stubborn scaling.

4. If necessary, replace with new rigid media pads, 

available only from your rigid media dealer. Aspen, 
expanded paper or other types of evaporative cooling 
pads will not work and will void your warranty.

5. Using a mild detergent, wash dirt and scale from the 

inside of the wet section cabinet. Wire brushing is not 
recommended. If finish is damaged or rusting is noted, 
repair as noted in the “Touch-Up” section. Rinse with 
fresh water.

6. Reinstall pads, making sure they are positioned 

correctly 

7. Reinstall back panel

Media Replacement

Wiring Diagram

Summary of Contents for SWH3000

Page 1: ...Use of extension cords is NOT recommended Congratulations You have purchased a product of superior performance and design which will give the best service when properly operated and maintained This gu...

Page 2: ...qualified to do so CAUTION Disconnect all electrical power to the cooler before attempting to install open or service your cooler Even while routinely inspecting or servicing the inside the cooler can...

Page 3: ...anges must be made Consult a qualified professional before making structural changes to the wall CAUTION When cutting or drilling into the wall do NOT damage electrical wiring or other hidden utilitie...

Page 4: ...6 1 8 below the bottom of the duct cutout Ensure the bracket is installed level and is centered in relation to the duct cutout Pre drill the holes and attach the brackets using the included lag screws...

Page 5: ...over drain bushing push drain bushing through bottom of cooler and tighten nut Screw plastic overflow standpipe into the drain bushing and tighten hand tight to prevent leakage Where conditions allow...

Page 6: ...ermal overload switch that will shut the motor and or the pump off if it overheats The motor and or pump can restart automatically when they cool down Page 5 To verify and check out the cooler install...

Page 7: ...INSPECTION CAUTION Do not allow pump to fall over and become submerged water will damage pump motor Clean water pump and hose assembly as follows 1 Unplug power supply cord from wall receptacle remov...

Page 8: ...pad and will remove more stubborn scaling 4 If necessary replace with new rigid media pads available only from your rigid media dealer Aspen expanded paper or other types of evaporative cooling pads...

Page 9: ...et screen clogged 1 Clean or replace media pads 2 Check water distributor system 3 Locate and free obstruction 4 Clear debris from trough 5 Clean or replace pump 6 Check for leaks and correct 7 Turn o...