3.4 Time & Date setup menu 
 
 
 

 

 
 
 

Figure 5:  Set Time and Date Screen 

 
Figure 5 shows the buttons for adjusting the time and date. Touch the + or – Buttons to adjust the time 
and date, then save, then exit to return to the main screen. 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PSSA-10K230M-50

Page 1: ...70I001 SOLID STATE HIGH POWER WIDE BAND AMPLIFIER MODEL PSSA 10K230M 50 OPERATING AND MAINTENANCE INSTRUCTIONS Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 Tel 408 916 5750 E Mail contact relia...

Page 2: ...ont Panel Status Indicators 18 5 0 PRINCIPALS OF OPERATION 5 1 Proper Usage and Warnings 20 6 0 Remote INTERFACE 6 1 Introduction 21 6 2 RS 232 21 6 3 ETHERNET 22 6 4 Remote Command Format 24 7 0 MAIN...

Page 3: ...performance and trouble free operation depends on you thoroughly reading through this manual and familiarizing yourself with its proper operation and usage Your Wide Band Amplifier comes with the foll...

Page 4: ...MAN 70009 REV A Page 4 of 35 FIGURE 1 0 OUTLINE DRAWING...

Page 5: ...screen 7 high resolution 800x480 color TFT Display that displays continuous forward and reflected power metering The display also provides the operator with operating status and self diagnostic fault...

Page 6: ...rameters by way of button switches located toward the right of the screen Pressing a button switch will toggle the switch position and will highlight its function Figure 2 Hardware Initialization Scre...

Page 7: ...MAN 70009 REV A Page 7 of 35 3 2 PMI Screen Figure 3 PMI Logo Screen The PowerMax Innovations logo screen it is only displayed for a few seconds and is shown in above...

Page 8: ...stem Information and Set Time Button Screen The Information screen displayed is the set time Model and version description screen it will be displayed for a few seconds should the set time icon be tou...

Page 9: ...of 35 3 4 Time Date setup menu Figure 5 Set Time and Date Screen Figure 5 shows the buttons for adjusting the time and date Touch the or Buttons to adjust the time and date then save then exit to ret...

Page 10: ...ure 6 OPERATE MENU The operating menu will come up in RF OFF Mode The values for Forward Power FWD Reflected Power RFL and metering should be zero The Gain will be at 100 at all times unless the Atten...

Page 11: ...e In this mode the Amplifier main DC power supply is turned on and the RF Modules number of modules used depends on the amplifier type are biased 2 The display will show the PS Voltage current and als...

Page 12: ...Mode w RF Power FIGURE 8 RF ON MODE 3 Place the unit in RF ON mode In this mode the RF Modules are biased 4 The display will show the RF Output power as the drive power is increased and also shows th...

Page 13: ...OPERATION OVERVIEW The Amplifier is designed to amplify a low level microwave signal and supply a high power CW output The Amplifier system function is accomplished primarily through the use of a Hig...

Page 14: ...MAN 70009 REV A Page 14 of 35 FIGURE 10 SYSTEM BLOCK DIAGRAM...

Page 15: ...MAN 70009 REV A Page 15 of 35...

Page 16: ...or CW Prime Power 220VAC 50 60 Hz single Phase 3 Wires Power Requirements 1KVA Functional Description The required voltages and currents to operate the amplifier are provided by the main 48VDC supply...

Page 17: ...nly show the temperature of of modules used If the temperature in any modules rises above the set limit the amplifier will revert to Standby and the Fault Indication on the front panel Display of the...

Page 18: ...REV A Page 18 of 35 Local Remote Switch RJ45 Ethernet Connector RF ON OFF Switch IEEE 488 connector Fault Reset Switch RF Output N Female TFT Status Display RF Input N Female FIGURE 11 0 REAR PANEL IL...

Page 19: ...indicate which fault had occurred Total RFON HOUR Elapsed time Indication on the TFT display presents total hours that the amplifier total or RF ON has been energized Remote The Remote will be indica...

Page 20: ...the amplifier using a calibrated 50 Ohm Pad to assist the operator in maximizing the performance of the Wide Band Amplifier The accuracy of the Metering is 5 dB nominal so to provide the operator wit...

Page 21: ...nal levels to more efficiently operate the amplifier refer to Paragraph 4 7 herein 5 1 3 Preamplifier The Preamplifier provides the proper drive levels to the RF Modules to obtain the proper Output Po...

Page 22: ...DCE data communication equipment The PMI Amplifiers have a RS 232 serial interface All amplifier functions can be controlled by coded messages sent over the interface bus via the 9 pin D type socket...

Page 23: ...TCP and the Internet Protocol IP which were also the first two networking protocols defined Today s IP networking represents a synthesis of two TCP IP uses four numbers to address a computer Each com...

Page 24: ...ocols and syntax of commands The GPIB command codes for the IFI Amplifier series are discussed on subsequent pages and for ease of identification the command codes are identified within the text by bo...

Page 25: ...See Remote commands below NOTES 1 ALL COMMANDS AND REQUESTS MUST CONSIST ENTIRELY OF UPPER CASE ALPHANUMERIC CHARACTERS 2 ALL VALUES DISPLAYED DO NOT SHOW THE ZEROS TO THE LEFT OF THE NUMBER VALUE 6 4...

Page 26: ...er Response Description RF OFF Go to RF OFF Mode RF OFF Brings the amplifier to RF OFF from RF ON mode RF ON Go to RF ON Mode PS TURN ON Brings the amplifier to RF ON from RF OFF mode RESET Fault Rese...

Page 27: ...escription NO WARNINGS No warning condition WARNING FWD PWR LIMIT WARNING RFL PWR LIMIT FAULT Returns Detailed Message HIGH TEMP FAULT High Temperature fault HIGH VSWR FAULT When VSWR is greater then...

Page 28: ...ON MUTEOFF Enables PAs Driver MUTE OFF REMOTE Put amp in RMT mode REMOTE ON TOTALH Total Hours TOTAL HOURS XXXXX Returns Total Hours RF ONH Total operating hours RF ON HOURS XXXXX Returns Operation H...

Page 29: ...r RS 232 or TCP IP for Ethernet remote Click OK 6 6 In Bits per Second select 9600 6 7 In Data Bits select 8 6 8 In Parity Select None 6 9 In Stop bits select 1 6 10 In Flow control select None 6 11 C...

Page 30: ...on None Example of response N A Hex value of example N A Command to read the amplifiers forward power ASCII String to amplifier POWERFWD cr lf Hex equivalent of string 0x50 0x4f 0x57 0x45 0x52 0x46 0x...

Page 31: ...servicing be required refer to Paragraph 7 3 7 2 1 TROUBLESHOOTING PROBLEM CAUSE SOLUTION COMMENTS TFT display blank No service voltages Check line power Check service voltages 12VDC 12Vdc 5VDC Connec...

Page 32: ...material 7 3 2 Return All Accessories In the interest of saving time and expediting the repair or calibration process return all the associated accessories described in Section 1 0 when returning the...

Page 33: ...efective after inspection by PMI This warranty shall not apply to any PMI product that has been disassembled modified physically or electrically damaged or any product that has been subjected to condi...

Page 34: ...MAN 70009 REV A Page 34 of 35 APPENDIX A TEST DATA SHEETS...

Page 35: ...ings Package PSSA 10K230M 50 Bill of Materials BOM INT 50129 Interconnect Diagram OLN 50038 Outline drawing Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 Tel 408 916 5750 E Mail c...