0507291010/260411/A T-Flex/CW
EN - 13
If the product does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
The following spare parts are available for the product (refer to
exploded view Fig. VI on page 40).
After life of the product, dispose it of in accordance with federal,
state or local regulations.
7
TROUBLESHOOTING
Symptom
Problem
Possible cause
Solution
Rotatable
hood does not
stay in desired
position.
Balance
problem.
Too much or not
enough friction in
hood hinge.
Adjust friction.
Refer to Fig. IV on
page 39;
A = vertical
movement;
B = horizontal
movement.
Arm does not
stay in desired
horizontal/
vertical/
diagonal
position
Balance
problem.
Spring loose.
Tighten spring.
page 39;
A = spring.
Too much or not
enough friction in
arm.
Adjust friction.
page 39;
B = friction.
Arm does not
stay in
retracted
position.
Movement
problem.
Counterweight
gets stuck.
Extend the arm
and retract it
again slowly.
Rope broken.
Replace rope.
Poor suction.
Extraction
arm does not
function
properly.
Throttle valve
closed.
Open throttle
valve.
Flexible hose(s)
torn or loose.
Mount correctly or
replace.
Bush(es)
damaged or loose.
Mount correctly or
replace.
8
SPARE PARTS
Article no.
Description
9880020010
Hose 500 mm (20 in.) (5 pieces)
Hose 1650 mm (65 in.)
0692000000
Polyester rope Ø 4 mm (0.16 in.)
0840101030
Bush Ø 203 mm (8 in.)
9823000000
Rotatable hood
RotaHood
, complete
9823000100
Throat rotatable hood, complete
9823000990
Throat rotatable hood HD, complete
9823003000
Rotatable hood
RotaHood
HD, complete
9824000010
Hinge set rotatable hood, incl. protection cover
9824000100
Rubber protection cover hood hinge
9
DISPOSAL