2
1
3
Inspection and maintenance:
Inspection/maintenance shall be done according to fol-
lowing scedule:
0-500
turn-outs/year every 16th week
500-1500
turn-outs/year every 12th week
1500-3000
turn-outs/year every 8th week
3000 +
turn-outs/year every 4th week
1. Check the compressed air systems mechanical
attachments and leakages on couplings, realease valve
and regulator.
2. Check/adjust the air pressure (max 1.0 bar).
3. Remove the hose assembly from the balancer and
check the hose, compressed air hoses, suspension
halter, MFD-valve and Grabber® . The safety disconnect
coupling should be disassembled and cleaned.
The hose assembly should be aligned prior to mounting
see " Alignement/mounting of hose assemby" in the
mounting instructions.
PUM_SBT_091102_EN
33/38
10.
MAINTENANCE INSTRUCTION
ATTENTION!
a. Service and maintenance only to be done by
qualified and trained persons ( in EU according
to TRGS 554.
b. Use sufficient climbing gear and safety guards
when working on a higher level than 2.0 meter.
c. Only carry out service and maintenance when
the system is fully disconnected from mains.
d. Be sure no vehicle can enter the station/bay
when carrying out service/maintenance.