![Plymovent KUA-160/2H Installation And User Manual Download Page 7](http://html1.mh-extra.com/html/plymovent/kua-160-2h/kua-160-2h_installation-and-user-manual_1569220007.webp)
0000101887/010920/B KUA-160
6
Floor mounting Ceiling mounting
Wall mounting
Fig. 4.2 Stanchion (PA)
For mounting of the arm to the wall bracket:
• proceed with paragraph
4.4.3 Arm mounting
TIP
Do a balance check of the arm before you fasten the
hoses. Refer to section 6.2.
• Remove the locknut M20 (A) from the hinge rod (E).
• Move the hose clamp (F) and the arm swivel ring (incl.
rubber collar) (D) over the hinge rod (E).
• Put the washer M20 (C) on the arm swivel ring (D).
•
Put the hinge rod (E) in the rotating flange (B).
• Put the hose (G) over the arm swivel ring (D).
• Use the rubber collar to make the connection airtight.
• Attach the hose (G) to the swivel ring (D) with the hose
clamp (F).
• Put the locknut M20 (A) on the hinge rod (E) and tighten it.
• Install the assembly to the wall bracket with the 8 bolts
M6x25 + washers M6.
Fig. 4.3
A
B
C
D
E
F
B
D
F
G
G
Mounting of the arm
For mounting of the hood:
• refer to paragraph
In case of a KUA-160/H ATEX:
• subsequently proceed with paragraph
4.4.4 Fan mounting
To install an extraction fan
7
on the arm, do the following.
• Put the fan on the wall bracket.
• Insert 4 bolts M6x25
8
through the bottom of the wall
bracket into the cage nuts of the fan housing.
• Fasten the bolts securely.
DESCRIPTION:
REV.:
DRAWING NO:
3RD ANGLE PROJECTION
-
0
-
DATE: -
MATERIAL: -
DRAWN: MKG
The information contained in this
drawing is the sole property of
PLYMOVENT. Any reproduction in part
or as a whole without written permission
of PLYMOVENT is prohibited.
UNITS: mm
SCALE: 1:20 (do not scale drawing)
SHEET 1 OF 1
A3
PROJECT: -
CUSTOMER: -
GENERAL TOLERANCES: -
®
DESCRIPTION:
REV.:
DRAWING NO:
3RD ANGLE PROJECTION
-
0
-
DATE: -
MATERIAL: -
DRAWN: MKG
The information contained in this
drawing is the sole property of
PLYMOVENT. Any reproduction in part
or as a whole without written permission
of PLYMOVENT is prohibited.
UNITS: mm
SCALE: 1:20 (do not scale drawing)
SHEET 1 OF 1
A3
PROJECT: -
CUSTOMER: -
GENERAL TOLERANCES: -
®
Fig. 4.4 Mounting of the fan
4.5
Mounting of the KUA-160/S
For mounting examples, refer to Fig. V on page
For mounting on a
stanchion
(PA):
• proceed with paragraph
For mounting on a
wall bracket
:
• proceed with paragraph
For mounting on a
mobile unit
:
• proceed with paragraph
4.5.1 KUA-160/S on a stanchion
•
Disassemble the rotating flange from the wall bracket and
change the position from bottom to top.
Fig. 4.5
Position of the rotating flange
7. Suitable types: refer to section 1.4
8. The bolts are supplied with the arm