background image

0507210010/010320/D FAN-28 

4

 

- Do not install the product in front of entrances and exits that 

must be used for emergency services. 

 

- Mind any gas and water pipes and electric cables.

 

- Make sure that the workspace is well illuminated. 

 

- Stay alert and keep your attention to your work. Do not 

install the product when you are under the influence of 

drugs, alcohol or medicine. 

 

- Air containing particles such as chromium, nickel, beryllium, 

cadmium, lead etc., should never be recycled. This air must 

always be brought outside the working area.

Use

WARNING!

Fire hazard! Do 

not

 use the product for:

 

- polishing applications in combination with 

grinding, welding or any other application that 

generate sparks 

(fibers from polishing or abrasive flap disks 

are highly flammable and pose a high risk of filter fires when 

exposed to sparks)

 

- arc-air gouging

 

-

extracting flammable, glowing or burning particles 

or solids or liquids

 

- extracting of aggressive fumes (such as 

hydrochloric acid) or sharp particles

 

- extracting dust particles that are released when 

welding surfaces treated with primer

 

- sucking cigarettes, cigars, oiled tissues, and other 

burning particles, objects, and acids

WARNING!

Explosion hazard! Do 

not

 use the product for 

explosion-hazardous applications, e.g.:

 

- aluminium laser cutting

 

- grinding aluminium and magnesium

 

- explosive environments or explosive substances/

gases

WARNING!

Do 

not

 use the product for:

 

- extraction of hot gases (more than 70°C/158°F 

continuously)

 

-

flame spraying

 

- oil mist

 

- heavy oil mist in welding fume

 

- extraction of cement, saw dust, wood dust etc.

 

- Inspect the product and check it for damage. Verify the 

functioning of the safety features. 

 

- During use, always use Personal Protective Equipment (PPE) 

to avoid injury. This also applies for persons who enter the 

work area.

 

- Check the working environment. Do not allow unauthorised 

persons to enter the working environment. 

 

- Protect the product against water and humidity.

 

-

Make sure the room is always sufficiently ventilated; this 

applies especially to confined spaces.

 

- Make sure that the workshop, in the vicinity of the product, 

contains sufficient approved fire extinguishers (suitable for 

fire classes ABC). 

 

- Do not leave any tools or other objects in or on the unit. 

Service, maintenance and repairs

 

- Always use Personal Protective Equipment (PPE) to avoid 

injury. This also applies for persons who enter the work area.

 

- Do not leave any tools in or on the product. 

 

-

Use sufficient climbing gear and safety guards when working 

on a higher level than 2 metres (local restrictions may 

apply).

ATTENTION

Fully disconnect the fan from the main before you 

carry out service, maintenance and/or repair jobs.

Personal protective equipment (PPE)

Wear respiratory protection and protective 

gloves during service, maintenance and 

repairs.

INSTALLATION

4.1 

Tools and requirements

You need the following tools and requirements to 

install the fan:

 

- basic tools

 

- electrical tools

4.1.1  To be sourced locally

 

- Hardware to install the mounting brackets  

NMB or TNB

 

- Mains cord

4.2 

Unpacking

Make sure that the product is complete. The 

package contains:

 

- extraction fan

 

- mounting material to install the fan on the wall brackets NMB 

or TNB

4.3 

Mounting

The mounting instructions of the fan depend on the selected 

wall bracket.

In case of mounting brackets type NMB, proceed with 

paragraph 4.3.1.

In case of mounting brackets type TNB, proceed with 

paragraph 4.3.2.

4.3.1  Mounting brackets NMB

Fig. 4.1

•  Install the NMB as described in the corresponding manual.
•  Instal the extraction arm as described in the corresponding 

manual.

• 

Install the fan (B) on the rotating flange (C) of the 

extraction arm with the supplied mounting material.

• 

Tighten the bolts firmly.

• 

Make sure that the seal between the conection flange and 

the fan is airtight.

Subsequently:

•  Connect the outlet opening (A) of the fan to:

 

- a spiral tube (Ø 160 mm); or

 

-

a flexible hose Ø 160 mm (CKS; ref. paragraph 1.4)

•  Make sure that all connections are airtight.

Summary of Contents for FAN-28

Page 1: ...www plymovent com Extraction fan FAN 28 Installation and user manual EN...

Page 2: ...installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover...

Page 3: ...ntains among other things the following data product name serial number supply voltage and frequency power consumption 1 2 General description The FAN 28 is an extraction fan that is especially design...

Page 4: ...and observe all instructions and directions given Do not change the order of the steps to perform Keep the manual with the product Users The use of this product is exclusively reserved to authorised...

Page 5: ...environment Protect the product against water and humidity Make sure the room is always sufficiently ventilated this applies especially to confined spaces Make sure that the workshop in the vicinity o...

Page 6: ...identification plate on the motor Connect the control equipment to the mains according to the separately supplied electrical diagram An arrow on the fan housing indicates the correct direction of rota...

Page 7: ...tion of false air Damaged or worn sealing material Replace the sealing material Vibrations in the fan Fan is not steady Imbalance in the fan Clean the fan blades 8 SPARE PARTS The following spare part...

Page 8: ...102305 0612010220 0000102306 0000102297 0708020150 Art no Description General 0000102291 Sealing ring 0000102297 Aluminium fan wheel 50Hz 0000102305 Housing FAN 14 28 MNF mobile units motor side 00001...

Page 9: ...www plymovent com 0507210010 010320 D FAN 28...

Reviews: