0507210010/010320/D FAN-28
2
PREFACE
Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
TIP
Suggestions and recommendations to simplify
carrying out tasks and actions.
ATTENTION
A remark with additional information for the user. A
remark brings possible problems to the user’s
attention.
WARNING!
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
CAUTION!
Denotes risk of electric shock.
WARNING!
Fire hazard! Important warning to prevent fire.
Personal protective equipment (PPE)
Instruction to use respiratory protection when you
do service, maintenance and repair jobs, as well as
during functional testing. We recommend to use a
half-face respirator according to EN 149:2001 +
A1:2009, class FFP3 (Directive 89/686/EEC).
Personal protective equipment (PPE)
Instruction to use protective gloves when you do
service, maintenance and repair jobs.
Text indicators
Listings indicated by “-” (hyphen) concern enumerations.
Listings indicated by “•” (bullet point) describe steps to
perform.
Service and technical support
For information about specific adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product. He will always be willing to
help you. Make sure you have the following specifications at
hand:
- product name
- serial number
You can find these data on the identification plate.
1
INTRODUCTION
1.1
Identification of the product
The identification plate contains, among other
things, the following data:
- product name
- serial number
- supply voltage and frequency
- power consumption
1.2
General description
The FAN-28 is an extraction fan that is especially designed to
remove welding fumes and gases that are released during the
most common welding processes.
The fan is intended and designed for use with extraction arms
and filter units.
1.3
Product combinations
1.3.1 Extraction arms and mounting brackets
You can use the FAN-28 in configurations with an extraction
arm of Plymovent. The table below shows which type of
additional mounting brackets you need in a specific
configuration.
Connection to
Mounting brackets
Extraction arm
T-Flex
TNB
T-Flex/CW
No additional
brackets required
Flex-2
TNB
Flex-3 | Flex-4
NMB
UltraFlex-3 | UltraFlex-4
NMB
UltraFlex-4/LC
NMB
NEC-2 | NEC-4
TNB
Other
Duct connection
TNB
1.3.2 Control equipment
Manual switch on/off, wall-mounted:
-
MPS range | Motor protection switch; specific type depening
on the connection voltage
In configurations of an extraction arm with WL (working light),
WL-AST (working light + automatic start/stop) and WCS
(welding cable sensor), you must install a thermal relay (NTR
range) in the control box (CB); the specific type depending on
the connection voltage.
1.4
Options and accessories
The following products can be obtained as an option and/or
accessory:
- SAS-160 | Duct silencer Ø 160 mm
-
CKS | Connection kit (flexible hose 1 m / Ø 160 mm + two
hose clamps)
1.5
Technical specifications
Physical dimensions and properties
Fan type
radial
Inlet diameter
Ø 200 mm (Ø 7.87 in.)
Outlet diameter
Ø 160 mm (Ø 6.30 in.)
Weight
15 kg (33 lbs.)
Performance
Unrestricted airflow
2400 m
3/h
(1413 CFM)
Speed:
- 50 Hz
- 60 Hz
2800 rpm
3400 rpm
Noise level
69 dB(A) according to ISO 3746
Electrical data
Power consumption
0,75 kW (1 HP)
Available connection
voltages
115V/1~/50Hz | 120V/1~/60Hz
230V/1~/50Hz | 230V/1~/60Hz
230V/3~/50Hz | 400V/3~/50Hz
400V/3~/60Hz
Max. start/stops per hour 30
Insulation class
F