5
2.3 POWER CONNECTIONS
POWER Linking: 3 units@110V
;
6 units@220V.
This product has an auto-ranging power supply that can work with an input voltage range of
100
–240 VAC, 50/60 Hz.
AC Plug
Connection
Wire (U.S.
Wire(Europe)
Screw Color
AC Live
Black
Brown
Yellow/Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
2.4 Data network requirements
Connect the DMX512 controller to the units in series. A DMX 512 data link is required in
order to control the fixture via DMX. The fixture has 3/5-pin XLR connectors for DMX data
input and output.
Each unit has 13 DMX channels so the DMX Addresses should increase by increments of 1
,
(Nx1)+1
,
(Nx2)+1
,
(Nx3)+1...
Any DMX address in the range from 001 to 512 may be used.
Connect the DMX-output of the first fixture in the DMX chain with the DMX-input of the next
fixture. Always connect one output with the input of the next fixture until all fixtures are
connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a
120 Ω resistor between Signal (–) and Signal (+) into a 3/5-pin XLR-plug and plug it in the
DMX-output of the last fixture.