The following describes how to calibrate the scanner:
1. The Calibration Sheet, marked with an arrow on either edge at both sides, is
used specially for
ADF Scanning
calibration.
2. Insert the special calibration sheet into the ADF of the scanner, with an arrow
toward the scanner buttons.
Attention
Please insert the special calibration sheet
included with the scanner. Alternatively you
may also use any plain white sheet of paper
sized in A4 (216 by 297 mm) instead; however,
the calibration effect may be less good than the
special calibration sheet.
3. Click
Start
>
All Programs
>
Your scanner model name
>
Calibration
Wizard
.
4. Click
Next
from the Calibration Wizard that pops up and then click
Calibrate
Now...
. Start to begin the Flatbed Reflective calibration process. After the
calibration is complete, click
OK
.
5. Click
Calibrate Now...
. Click on the
Start
button to begin the ADF calibration
process.
6. The scanner pulls the calibration sheet through the scanner, which completes
this scanner calibration. After the calibration is complete, click
OK
and then
click
Finish
.
S
TANDBY
M
ODE
5
To save power consumption, the scanner will enter the standby mode after it is idle
for a while. You may disable the standby mode or define an idle time for the scanner to
automatically enter the standby mode.
5
This function may or may not be available depending on the scanner model you purchase.
36