PLUSLITE BAT LED User Instructions Download Page 11

11 

DMX512 control console control mode 

In  the  'User  setting'  interface,  press  the 

ENTER

  button  to  confirm.  The 

'Channel' mode is displayed. Use the 

UP / DOWN

 keys to select '

6CH

' or 

'

10CH

'.  Press  the 

ENTER

  button  to  automatically  jump  to  'DMX512' 

Address  code  setting),  use  the 

UP  /  DOWN

  buttons  to  adjust  the  address 

code  you  want  to  set  between  1  and  512.  At  this  point  you  can  receive 
DMX512 console control signal. 

If you want to use this function, please refer to the explanation below to set 
DMX512 address of 4 fixtures 
6CH mode: 1.: A001, 2: A007, 3: A013 4: A019 
10CH mode: 1.: A001, 2: A0011, 3: A021 4: A031 

Master-slave built-in program control 

When  connecting  multiple  fixtures  with  the  commander  mode,  press  the 

ENTER 

button to confirm 

'OK!'

, Except for the first fixture, and the other 

fixtures in the back select '

Slave

' (slave mode). When you receive the host 

signal, the interface will appear '

connection

' prompt, if you disconnect the 

DMX512  signal,  the  interface  will  appear  '

Disconnect'

  prompt,  if  press 

ENTER

 or 

MENU 

button, the display will exit to the previous mode. The 

first fixture is used as the master, and all the show modes  can be selected. 
The slave will be synchronized by the master to perform the same action. 

WIFI operating mode 

In  the  'User  setting'  interface,  press  the 

ENTER

  button  to  select  '

WIFI'

 

(WiFi  mode)  and  press  the

  ENTER 

button.  To  connect  control,  open  the 

phone  settings  function,  find  the  wireless  and  network 

WLAN 

items, 

connected to the name of LED-XXX device. As shown in the picture 

Summary of Contents for BAT LED

Page 1: ...BAT LED Battery Led Light User Instructions https www piu39av com pluslite lighting...

Page 2: ...ser should comply with warning item and manual any misuse cause of the damages are not included in our guarantee and also can not be responsible for any malfunction problem owing to ignore the manual...

Page 3: ...t temperature is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85 DO NOT touch the housing bare ha nd during its operation Turn off the pow...

Page 4: ...cure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be...

Page 5: ...ell phone Led home language Chinese or English 5 Static color option 6 colors dimming value 0 255 Strobe Speed 0 20 6 Macro function 32 colors optional 7 Auto color skip function Speed 0 20 8 Color gr...

Page 6: ...7 255 15 The battery logo in the upper right corner of the interface can be turned on or off by setting the logo appears such as the product without the battery can be set to off 16 Screen saver setti...

Page 7: ...7 4 Menu...

Page 8: ...8...

Page 9: ...ess the MENU button to enter the main menu the display will display the corresponding menu function when you press the MENU button again select the next menu function such as repeatedly press the MENU...

Page 10: ...ton you can adjust the required address code between 1 and 512 After selecting the parameters will be saved automatically When you receive a 512 signal the interface will appear Connection prompt If y...

Page 11: ...g multiple fixtures with the commander mode press the ENTER button to confirm OK Except for the first fixture and the other fixtures in the back select Slave slave mode When you receive the host signa...

Page 12: ...after storage and then select the direct control there will be color control interface then the corresponding Mode operation Different mobile phone operation page may be somewhat different but the fu...

Page 13: ...0 69 Gradual change 10 channel control speed 70 89 Sudden change 10 channel control speed 90 109 RED 110 129 GREEN 130 149 BLUE 150 169 WHITE 170 189 YELLOW 190 209 PURPLE 210 299 Skip change by sound...

Page 14: ...s cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on conn...

Page 15: ...s at least every 20 days Clean the internal optics at least every 30 60 days 9 Precautions Precautions for lithium battery 1 Lithium battery for the first time into the lamp you should put the end of...

Page 16: ...fter unpacking for damage 2 Check the battery open circuit voltage is normal normal should be 12V 10 3 When carrying the battery to hold the bottom do not mention the terminal parts 4 The battery shou...

Page 17: ...2 W 6 in1 RGBW A UV LED IP20 Any safe working position 48W 6 10 Channels DMX 512 sound master slave auto IRC WiFi optional Net 2 4Kgs Gross 4 5Kgs 14cm 13cm 27cm 2 Year Please Note Specifications and...

Reviews: