'Choose pattern' (Selection mode) 

Select  Choose  pattern,  press

  ENTER 

button  to  confirm,  the  display  will 

display the corresponding function menu. Such as static color, macro color 
mixing,  recognition  mode,  voice  mode.  Press  the 

UP  /  DOWN

  button  to 

select between the functions. Pressing the 

ENTER

 key causes the display 

to  advance  to  the  next  level.  Pressing  the 

MENU

  key  will  exit  to  the 

previous menu level and the parameter will be saved automatically. 

'User setting' 

Select 'user setting' (console control mode set up) 
,  Press  the 

ENTER

  key  to  confirm,  the  display  will  enter  the  channel 

option,  use  the 

UP  /  DOWN

  buttons  to  select  '6  CH',  '10  CH'.  When  the 

ENTER

 button is  pressed again,  the menu  will automatically jump to  the 

DMX512  address  setting  mode, 

UP/DOWN

  button,  you  can  adjust  the 

required  address  code  between  1  and  512.  After  selecting,  the  parameters 
will  be  saved  automatically.When  you  receive  a  512  signal,  the  interface 
will  appear

  'Connection’ 

prompt.  If  you  disconnect  the  512  signal,  the 

interface  will  appear 

'Disconnect'

  prompt,  if  you  press  the 

ENTER

  or 

MENU

 button, the display will exit to the previous menu level mode. 

Slave mode 

Select  'slave'  and  press  the 

ENTER

  button  to  confirm  and  '

OK

'  will  be 

displayed. The interface will appear '

connection'

 prompt, if the host signal 

is 

disconnected,

 the interface will appear 'disconnect' prompt, if you press 

the  button,  press  the  button  to  enter  the  main  menu, 

ENTER

  or

  MENU 

button, the display will exit to the previous menu mode 

'

System setting' mode

 

Select "System settings" and press the 

ENTER 

button to move to the next 

level.  Use  the 

UP  /  DOWN

  buttons  to  select  a  different  setting  for  each 

function. Press the 

ENTER

 or 

MENU

 button to exit to the previous menu 

mode 

Summary of Contents for BAT LED

Page 1: ...BAT LED Battery Led Light User Instructions https www piu39av com pluslite lighting...

Page 2: ...ser should comply with warning item and manual any misuse cause of the damages are not included in our guarantee and also can not be responsible for any malfunction problem owing to ignore the manual...

Page 3: ...t temperature is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85 DO NOT touch the housing bare ha nd during its operation Turn off the pow...

Page 4: ...cure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be...

Page 5: ...ell phone Led home language Chinese or English 5 Static color option 6 colors dimming value 0 255 Strobe Speed 0 20 6 Macro function 32 colors optional 7 Auto color skip function Speed 0 20 8 Color gr...

Page 6: ...7 255 15 The battery logo in the upper right corner of the interface can be turned on or off by setting the logo appears such as the product without the battery can be set to off 16 Screen saver setti...

Page 7: ...7 4 Menu...

Page 8: ...8...

Page 9: ...ess the MENU button to enter the main menu the display will display the corresponding menu function when you press the MENU button again select the next menu function such as repeatedly press the MENU...

Page 10: ...ton you can adjust the required address code between 1 and 512 After selecting the parameters will be saved automatically When you receive a 512 signal the interface will appear Connection prompt If y...

Page 11: ...g multiple fixtures with the commander mode press the ENTER button to confirm OK Except for the first fixture and the other fixtures in the back select Slave slave mode When you receive the host signa...

Page 12: ...after storage and then select the direct control there will be color control interface then the corresponding Mode operation Different mobile phone operation page may be somewhat different but the fu...

Page 13: ...0 69 Gradual change 10 channel control speed 70 89 Sudden change 10 channel control speed 90 109 RED 110 129 GREEN 130 149 BLUE 150 169 WHITE 170 189 YELLOW 190 209 PURPLE 210 299 Skip change by sound...

Page 14: ...s cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on conn...

Page 15: ...s at least every 20 days Clean the internal optics at least every 30 60 days 9 Precautions Precautions for lithium battery 1 Lithium battery for the first time into the lamp you should put the end of...

Page 16: ...fter unpacking for damage 2 Check the battery open circuit voltage is normal normal should be 12V 10 3 When carrying the battery to hold the bottom do not mention the terminal parts 4 The battery shou...

Page 17: ...2 W 6 in1 RGBW A UV LED IP20 Any safe working position 48W 6 10 Channels DMX 512 sound master slave auto IRC WiFi optional Net 2 4Kgs Gross 4 5Kgs 14cm 13cm 27cm 2 Year Please Note Specifications and...

Reviews: