SFP-H / SFP-H-7 SERIES
with PIPM-R-7
User’s Manual
24 of 26
Static - Assigns a static IP address manually. The factory
default static IP address: 192.168.0.1.
IP Address - IP Address determines a static IP address to be used for TCP/IP networking. Consult your
network administrator about how to set this value.
•
If IP Address Type is set to DHCP, the IP address is set automatically by the network DHCP server
and cannot be entered here.
•
If IP Address Type is set to Static, enter an IP address compatible with your LAN here. Also enter a
netmask and default gateway address in the following two parameters. Click Apply when you are ready to
apply all three entries.
•
If IP Address Type is set to DHCP and there is a DHCP failure, the IP address is set to the static IP
address.
Netmask - Netmask determines the subnet mask to be used for TCP/IP networking.
•
Enter a subnet mask compatible with your LAN. This is only needed for Static IP configurations. The
factory default Subnet Mask is 255.255.255.0
•
If IP Address Type is set to DHCP, the Subnet Mask is set by the DHCP server and cannot be changed
by the user.
Default Gateway - Default Gateway determines the gateway or router used on your LAN for TCP/IP
networking.
Without a properly configured default gateway (whether you have a router/ gateway or not), your PIPM-
R-7 will be unable to see other PIPM-R-7 units on the network, although you may still be able to control
this PIPM-R-7 via a web browser. Also, without a proper gateway defined, the discovery feature on the
Network web page will not list other units on the network.
•
Enter a default gateway or router address. This is only needed for Static IP configurations. The
factory Default Gateway is 192.168.0.1.
•
If IP Address Type is set to DHCP, the Default Gateway is set by the DHCP server and cannot be
changed by the user.
MAC Address - Reports the connected PIPM-R-7 unit’s Media Access Control
Address.
Link State - Reports the current status of the Ethernet connection.