Do  not  place  the  unit  in  a  hot  environment  leading  to  too  high  operating 
temperatures. (H-No.: HW1.3.1) 

 

Do not place the unit in a location where steam flows directly to the device. 

 

Do  not  place  the  unit  near  heat  generating  devices  or  a  humidifier.  (H-N.: 
HW1.3.1) 

 

Do not place the unit in an inflammable gas environment. (H-No.: HW2.2.7) 

 

 

To avoid danger of suffocation, keep the plastic packing bags away from newborns and 
children. 

 

 

To disconnect the power cord, grasp the plug firmly and pull. Tugging on the cord may 
damage and result in fire, electric shock or burn. 

 

 

Use the correct voltage. 

 

The unit is designed for use with a specific voltage only. Connection to another 
voltage than specified in this User Manual may cause fire, electric shock, burn or 
equipment damage. 

 

Do not overload your power circuit, as this may result in fire, electric shock  or 
burn. 

 

 

Handle the power cord with care. If the power cord is broken, stop using it immediately. 
Using a broken power cord may result in fire, electric shock or burn. 

 

Do not put the power cord under the unit or heavy objects. 

 

Do not pull up or twist the power cord. 

 

 

Never touch the plug and power cord if it begins to thunder. Touching them may result 
in electric shock or burn. 

 

 

Do not touch a damaged LCD panel directly with bare hands. The liquid crystal that may 
leak from the panel is poisonous. Prevent to get it into the eyes or mouth. If any part of 
the skin or body comes in direct contact with the panel, please wash thoroughly. If some 
physical symptoms result, please consult your doctor. 

 

 

Follow local regulations or laws for safe disposal. 

 

 

Handle with care when carrying the unit. Disconnect the power cord and data cables and 
remove  the  optional  unit.  Moving  the  unit  with  the  cord  or  the  option  attached  is 
dangerous. It may result in injury. (H-No.: HW1.4.1) 

 

 

Do not block the ventilation slots of the cabinet. 

 

Do not place any objects on the ventilation slots. 

 

Do not install the unit in a closed space. 

 

Do not use the unit laid down or upside down. 

 

Blocking  the  ventilation  slots  prevents  proper  airflow  and  may  result  in  fire, 
electric shock, burn or equipment damage. (H-No.: HW1.3.2, HW4.3.1) 

 

 

Do not touch the plug with wet hands. Doing so may result in electric shock. 

 

Summary of Contents for MED-TAB v.2

Page 1: ...PUBLIC MED TAB v 2 INSTRUCTIONS FOR USE PUB INT EN 002TR 2017 PLUM Medical Solutions GmbH Release date 22 05 2017...

Page 2: ...ptional 9 2 6 Leather Case 10 2 7 Touch Pen 10 2 8 Grayscale adjustment according to DICOM Part 14 GSDF 11 2 9 Climatic and ambient conditions 11 2 10 MED TAB Characteristics 11 3 Getting started 12 3...

Page 3: ...lowing wide viewing angles and the matrix size or resolution is 1920 x 1080 pixels 2MP There is one REGULAR display MODE to visualize non medical images and one DICOM MODE factory calibrated display m...

Page 4: ...thcare professionals It is recommended to place the device on a desk using the rotating case stand either in portrait or landscape mode without direct flare on the screen The ambient should be less th...

Page 5: ...Touch pen Switching Power Adaptor for MED TAB v 2 incl plugs for US UK EU and CN Micro USB to USB cable Quick start guide We recommend operating the MED TAB using the leather case to protect the devi...

Page 6: ...MED TAB v 2 Instructions for Use PUB INT EN 002TR 6 iQ VIE W 2 2 MED TAB layout Ambient light sensor Volume keys DICOM touch button Touch Screen Speaker Power Lock Button...

Page 7: ...TAB v 2 Instructions for Use PUB INT EN 002TR 7 iQ VIE W Camera Microphone Power connector Headset jack USB Connector USB Connector Mini HDMI connector Micro SD Slot Reset Volume keys Power Lock Butt...

Page 8: ...e and device malfunction Always use the Switching Power Adaptor for MED TAB v 2 for charging and operation Make sure the power connector is fully connected to the power socket The power adaptor must b...

Page 9: ...sary stubborn stains can be removed by moistening part of a cloth with water to enhance its cleaning power CAUTION Danger of incorrect image analysis results Do not scratch the display surface Be care...

Page 10: ...ch pen allows a dirt free usage of the MED TAB and hence preserves its image quality The supplied touch pen will provide the most accurate measurements for diagnostic purposes CAUTION Danger of incorr...

Page 11: ...4 GSDF specification see chapter 4 CALCON Grayscale adjustment tool 2 9 Climatic and ambient conditions Key Action Operating Temperature 10 C 35 C Air pressure 600 hPa 1100 hPa Operating Humidity 30 9...

Page 12: ...ld the Power button for 3 seconds and then select Power off Confirm the shutdown by OK 3 3 Switching between DICOM and regular display modes Push the DICOM label at the bottom centre and hold it for 3...

Page 13: ...a mouse for any measurements with a connected PACS Never use fingers or other tools due to inaccurate measurements H No HW4 2 1 3 6 Locking and unlocking the touch screen and the keys To lock unlock...

Page 14: ...on bar all background apps will be shown Simply swipe an app to the side to close it 3 10Opening the ambient light indicator MED TAB CALCON is pre installed on every MED TAB To open this app please lo...

Page 15: ...he screen list all nearby wireless networks If not please disable and re enable the Wi Fi switch at the top 5 Look up your network name and click on it 6 Please enter the appropriate wireless password...

Page 16: ...rily for use in health care facilities without direct contact to patients no applied part If the device emits smoke smells like something is burning or makes a strange noise disconnect all power conne...

Page 17: ...in fire electric shock or burn Do not put the power cord under the unit or heavy objects Do not pull up or twist the power cord Never touch the plug and power cord if it begins to thunder Touching the...

Page 18: ...ncil or pen except the supplied Touch Pen as this may result in damage to the panel Do not attempt to brush with tissues as this may scratch the LCD panel NOTICE Danger of patient data breach We recom...

Page 19: ...o or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures o Reorient or r...

Reviews: