Pressure recorder MacR6-P 

Installation manual v1.0 

– December 2017

 

 

 

  

 

6.  CONFIGURATION PARAMETERS

 

 

 

 

Main application window presents parameters necessary for proper device operation. 
 
Additional parameters: 

o

 

PIN code to SIM card 

o

 

Device password (by default: 4096) 

o

 

Localization parameters 

 
 

NOTE: Application is designed for whole MacR6 product family. Types of presented pa-
rameters can be different for each product type.

 

 

 

Choosing "MORE PARAMETERS" presents options common for bigger amount of measuring sites. 

 
Values able to adjust: 

o

 

diagnostic  phone  number  (i.e.  installers  cell  phone  number  which  will  get  the  SMS 
message  with  installation  summary).  Way  of  typing:  XXYYYYYYYYYYY  where  XX  - 
country destination number w, YYYYYYYYYYY - phone number 

o

 

data server address - way of typing: address:port, i.e. www.ewebtel.com:80 

o

 

time synchronization option (winter/summer/auto change) 

 

 

Choosing "OPTIONS" presents additional parameters: 

 

o

 

Info - device nameplate, information about last measured GSM range signal value  - 
CSQ, device clock 

o

 

Clock programming - synchronizing devices clock with the smartphone including time 
synchronization options (winter/summer/auto change) 

o

 

Pressure limits - MacR6-P allows for setting four pressure limits - low limit warning and 
exceedance, high limit warning and exceedance. After exceeding the warning level user 
will get the information about exceedance risk. 

o

 

Service APN - APN used for communication with FTP server. 
 
 

NOTE: It is essential to ensure if the recorder clock is set correctly. If not, it is required 
to set it using menu OPTIONS and Clock programming.

 

 

Summary of Contents for MacR6

Page 1: ...s no need to remove the battery to insert the SIM card In the next step put the device together and tighten the screws with 0 65 0 75Nm momentum SIM card and antenna assembly is allowed only out of th...

Page 2: ...pheres are prescribed in Directive 1999 92 EC of the European Parliament and of the Council of 16 December 1999 ATEX 137 Worker Protection Directive Installation environment must guarantee the strong...

Page 3: ...ressure sensor assembly it is recommended to perform SEr 8 menu to begin pressure measurement test measurement every 5 seconds for one minute Value of pressure will be shown on LCD 4 CONNECTION WITH S...

Page 4: ...y destination number without YYYYYYYYYYY phone number o data server address way of typing address port i e www ewebtel com 80 o time synchronization option winter summer auto change Choosing OPTIONS p...

Page 5: ...ay Day of sending report to the server parameter ignored if Schedule Type 1 Registration Report Hours Decimal value of additional report hours binary vector extended info in user manual Report Delay D...

Page 6: ...con the blinking data sending icon will appear In the end the device will proceed to normal work showing periodically date hour and registered parameters value All of mentioned icons should flash cons...

Page 7: ...Description 0 not installed P pressure sensor X measurement range i e 0 1G 0 10 kPa 6G 0 600kPa 6A 80 600kPa abs DI DO 0 1 lub 2 digital inputs or outputs amount 2G modem 2G 3G modem 3G Sample markin...

Reviews: