8.

 

Support of the wireless room panel 

8.1

 

Controlling of the wireless room 

panel 

Device  is  equipped  with  a  screen  and  touch 
panel. 

 

Press  corresponding  symbols  on  the  screen 
in order to select position from the menu.  
The symbols mean:   

-  w selection of the main Menu; 

-  /  +  -  decrease/increase  the  value  of  the 
selected parameter; 

/

 - scroll the parameters list up/down; 

- exit a chosen Menu position or cancel a 

parameter setting; 

- return back to the main screen; 

- enter the  Menu position or  confirm the 

setting of the selected parameter; 

-  information  concerning  the  selected 

Menu position. 

8.2

 

Main screen 

 

 

 

 
 
Legend: 
1.

 

Name of the wireless room panel defined 
by the user. 

2.

 

Current measured temperature inside the 
room. 

3.

 

Wireless room panel operation mode: 

 

Schedule,  

 

Economy,   

  

Comfort,  

 

Out of home, 

 

Airing,  

 

Party,  

 

Holidays, 

 

Antifreeze, 

 

Loading HUW.  

4.

 

Active heating signaling. 

5.

 

Symbol of the selected device: 

 Boiler,  

Room panel,  

  

  Number  of  the  panel  which  the 

current main screen is displayed for,   
6.

 

Clock and weekday. 

7.

 

Main screen change button. 

8.

 

Current  external  temperature  (available 
only  with  a  weather  sensor  connected  to 
the main controller). 

13 

11 

10 

12 

Preset  
temperature 

 

Summary of Contents for eSTER x80

Page 1: ...ISSUE 1 1_EN WIRELESS ROOM PANEL eSTER_x80 FOR HEATING CIRCUIT CONTROLLERS 06 2019 ISM_xSMART the ISM_xSMART radio module is standard equipment for the wireless room panel ONLY COOPERATES WITH ecoMAX...

Page 2: ......

Page 3: ...NTROLLER ALARMS 7 8 11 SETTINGS 8 8 11 1 Hysteresis 8 8 11 2 Temperature correction 8 8 11 3 Screen brightness 8 8 11 4 Changing the language 8 8 11 5 PARENTAL LOCK 8 8 11 6 SOFTWARE UPDATE 8 8 11 7 S...

Page 4: ...ly industrialized buildings 3 Applied symbols In this manual the following graphic symbols are used the symbol indicates additional advice and information the symbol indicates important information Ca...

Page 5: ...sition from the menu The symbols mean w selection of the main Menu decrease increase the value of the selected parameter scroll the parameters list up down exit a chosen Menu position or cancel a para...

Page 6: ...ode in which it has been operating before the Out of home mode was set The symbol is displayed on the panel screen 8 3 5 Airing Selection of this mode will result in closing the mixing valves and swit...

Page 7: ...time period set the indicator 2 to a starting hour of time zone with the use of buttons set the comfort day or economic night temperature with the use of button set the indicator 2 to an ending hour o...

Page 8: ...8 11 6 Software update Enables updating the software with the use of a microSDHC memory card inserted into a slot in the panel enclosure in all connected devices controller additional modules control...

Page 9: ...iring function with the radio module for 4 minutes The correct pairing will be confirmed by a message on the screen of the wireless room panel 8 11 13 Information The Information menu displays the str...

Page 10: ...main controller socket using a 2 wire cable which should be connected in accordance with point 12 omitting the connection of the D and D signals To connect the room panel power supply you can use a 2...

Page 11: ...he pairing mode will be activated for 4 minutes during this time the room panel with the radio module should be paired in accordance with point 8 11 12 During the active pairing mode you can pair in t...

Page 12: ...els is possible only when the radio module program is fully compatible with the main controller To check if the main controller program is fully compatible with the radio module select the tab in the...

Page 13: ...adio module 2 main controller Connection of the module to the ecoMAX860P1 P2 D1 D2 1 radio module 2 main controller Connection of the module to the ecoMAX860P3 D3 1 radio module 2 main controller Conn...

Page 14: ...e main controller is equipped with TOU CH control panel colored with a touch panel only one room panel can be supplied directly from the controller module terminal 31 Panels 2 and 3 have to be supplie...

Page 15: ...TOUCH type panels simultaneously If the main controller is equipped with a standard control panel version with a knob two room panels can be supplied directly from the controller module terminal 46 T...

Page 16: ...equipped with TOUCH control panel colored with a touch panel only one room panel can be supplied directly from the controller module socket G4 Panels 2 and 3 have to be supplied by the additional pow...

Page 17: ...e supplied by the additional power adapter 12 VDC min 0 5 A Connection with ecoMAX910R1 ecoMAX920P1 If the main controller is equipped with a standard control panel version with a knob or TOUCH contro...

Page 18: ...5 868 MHz Transmission power of the wireless room panel and radio module 20 mW 13 dBm Radio network topology One radio module and many subordinate room panels Display Graphic 480 x 272 pix with touch...

Page 19: ......

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Reviews: