![Pluggit APFF Operating And Installation Instructions Download Page 5](http://html.mh-extra.com/html/pluggit/apff/apff_operating-and-installation-instructions_1568366005.webp)
3
II VOC and humidity sensor for Avent P190/P310/P460
Englis
h
3. Unscrew the screws (4).
4. Fold the cover (5) upwards in service position.
5. Carefully extract rubber block (6).
6. Place humidity sensor (7) or VOC sensor (8) at a distance
of approx. 50 mm (A) in the rubber block (6).
7. Install rubber block (6) in the room ventilation unit and
lay cable of the sensor or the sensors to the main board.
8. Connect humidity sensor to J23 and VOC sensor to J5 of
the main board (9).
9. Fold down cover (5) and tighten with screws (4).
10. Tighten front cover (3) at the room ventilation unit.
4
4
M+P-26A-0890
5
M+P-26A-0905
7
8
A
6
M+P-26A-0920
2
9
USB
J5
J23
J18
J17
J16
M+P-26A-0921