Light source:

Semiconductor laser diode
635-670 nm, visible

Working range:

+/- 100 feet

Accuracy:

<1/8” @ 30 Feet
(<3mm @ 10 meters)

Leveling:

Automatic

Leveling range

+/- 6

o

Power supply:

3AA batteries
alkaline or rechargeable

Operating time:

+25 hours continuous use with
single beam; 12.5 hours both
beams

Operating temp:

0

o

F to 122

o

F

(-18

o

C to 50

o

C)

Storage temp:

-40 F to 158

o

F

(-40

o

C to 70

o

C)

Indicator:

Green light: ON
Red light: EXCEEDS TILT/
TILT OVERRIDE #4
Amber light: BATTERY LOW

Environment:

Water resistant; not submersible

Dimensions:

2” x 2-7/8” x 3-3/8”

Weight:

10 oz.(.28kg) (including batteries)

We recommend that you check your PLS2
periodically in order to assure its accuracy.

TO CHECK LEVEL:
Choose two interior walls approximately 15’-0”
apart (see Fig. 1). You can use 2 x 4s for targets.

Turn on the PLS2 to setting #1 (level). With the
PLS2 six inches away from and facing target #1,
carefully mark the center of the line. Label this
mark A1. Swivel the laser 180º and mark the cen-
ter of the line on target #2. Label this mark B1.

Move the PLS2 six inches away from and facing
target #2. Carefully mark the center of the line.
Label this mark B2. Swivel the laser 180º and
mark the center of the line on target #1. Label
this mark A2.

You now have two centers of elevation at each
target. Carefully measure the distance between
centers of each set of marks. If there is a differ-
ence, subtract one measurement from the other.
This calibration method magnifies any error by a
factor of two. Therefore divide any difference by
two to find the true error. Your PLS2 should have
an error of no greater than 1/8in. within 30ft.

Choose a door jamb with 8’-0” clear on each side
of the door. Turn on your PLS2 laser to setting #2
(plumb). With your laser at point A, make two
marks on the floor: the first at 8’-0” from point A
centered on door header above (mark this point
B), the second 16’-0” from point A (mark this point
C). Without moving the laser, make a third mark
on the door header (mark this point D).

Move the laser to point C,

exactly

align the beam

with point B, and notice where the beam falls at
point D. If it is within a “light” 1/16” of point D, the
laser is in calibration.

This product is warranted by PLS

·

Pacific Laser

Systems to the original purchaser to be free from
defects in material and workmanship under nor-
mal use for a period of one year from the date of
purchase. During the warranty period, and upon
proof of purchase, the product will be repaired or
replaced (with the same or similar model at our
option), without charge for either parts or labor,
through PLS. The purchaser shall bear all ship-
ping, packing and insurance costs. Upon comple-
tion of the repair or replacement, the unit will be
returned to the customer, freight prepaid. The war-
ranty will not apply to this product if it has been
misused, abused or altered. Without limiting the
foregoing, battery leakage, dents or gouges to the
plastic housing, broken optic windows, damage to
the switch/LED membrane are presumed to result
from misuse or abuse. Tampering with or removal
of the caution or
certification labels voids this warranty.

Neither this warranty nor any other warranty,
express or implied, including implied warranties
of merchantability, shall extend beyond the
warranty period. No responsibility is assumed for
any incidental or consequential damages. This
warranty gives you specific legal rights, and you
may have other rights which vary
from state to state.

There is nothing an owner
can do in the way of service
or maintenance on PLS
tools. Contact PLS or your
local service center for
repairs

A

D

C

B

Target #1

Target #2

PALM LASER

PLS

2

®

PALM LASER

PLS

2

®

PLS Lab Technicians

A1

+

A2

B1

+

B2

-

15’

If level & plumb are within
specification, square will
be in specification.

Summary of Contents for PLS2 Palm Laser

Page 1: ...OR PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE PLS2 complies with US FDA standards 21 CFR 1040 10 and 11 These labels are attached to every PLS laser These are not to be removed or defaced PLS 2550 KERNER BLVD SAN RAFAEL CA 94901 WWW PLSLASER COM AVOID EXPOSURE LASER RADIATION EMITTED FROM THIS APERTURE PLS2 Palm Laser ON OFF BUTTON LED 800 601 4500 S N ...

Page 2: ...two marks on the floor the first at 8 0 from point A centered on door header above mark this point B the second 16 0 from point A mark this point C Without moving the laser make a third mark on the door header mark this point D Move the laser to point C exactly align the beam with point B and notice where the beam falls at point D If it is within a light 1 16 of point D the laser is in calibration...

Page 3: ...ítulo J Estas etiquetas están adheridas a todos los productos láser de PLS No deben quitarse ni borrarse PLS 2550 KERNER BLVD SAN RAFAEL CA 949011 WWW PLSLASER COM EVITE LA EXPOSICIÓN RADIACIÓN LÁSER EMITIDA A TRAVÉS DE ESTA ABERTURA PLS2 Palm Laser LED DEL BOTÓN ON OFF LED PPLS2 CUMPLE LOS ESTÁNDARES DE FUNCIONAMIEN TO DE LA FDA 21 CFR SUBCAPÍTULO J NÚMERO DE SERIE MFG D PRECAUCIÓN RIESGO DE RADI...

Page 4: ... materiales y mano de obra en condiciones normales de trabajo durante un perio do de un año desde la fecha de adquisición Durante este periodo de garantía y tras pre sentación de prueba de compra el producto será reparado o sustituido por el mismo producto o por un modelo similar según nuestro criterio sin cargos por piezas o mano de obra a través de PLS El comprador asumirá los gastos de envío em...

Page 5: ...apitolo J Queste etichette sono applicate ad ogni laser PLS Non rimuoverle né danneggiarle PLS 2550 KERNER BLVD SAN RAFAEL CA 94901 WWW PLSLASER COM EVITARE L ESPOSIZIONE A RADIAZIONI LASER EMESSE DA QUESTA APERTURA PLS2 Palm Laser PULSANTE ON OFF LED PLS2 RISPETTA GLI STANDARD DI PRESTAZIONE FDA CFR 21 SOTTOCAPITOLO J DATA DI PRODUZIONE MFG D ATTENZIONE EMISSIONE RADIAZIONI LASER QUANDO APERTO NO...

Page 6: ...ystems la garanzia all acquirente origi nario copre i difetti di produzione o dei materiali utilizzati per un periodo di un anno dalla data di acquisto a condizione che lo strumento sia utiliz zato in modo idoneo Durante il periodo di garanzia in presenza della prova di acquisto il prodotto verrà riparato o sostituito gratuitamente con un modello identico o simile a scelta dalla PLS Le spese di im...

Page 7: ...TZEN SIE SICH NICHT DER LASERSTRAHLUNG AUS DIE VON DIESER ÖFFNUNG AUSGEHT PLS2 Palm Laser ON OFF KNOPF LED PLS2 ERFÜLLT DIE FDA LEISTUNGSNORMEN 21 CFR UNTERKAPITEL J SERIENNUMMR FABRIZIERT VORSICHT LASERSTRAHLUNG WENN OFFEN STARREN SIE NICHT IN DEN STRAHL ODER SEHEN IHN DIREKT MIT OPTISCHEN INSTRUMENTEN AN PATENT HÄNGIG REG US PATENTAMT PLS 2550 KERNER BLVD SAN RAFAEL CA 94901 V O R S I C H T LASE...

Page 8: ...kelfunktion auch A D C B Ziel Nummer 1 Ziel Nummer 2 PALM LASER PLS2 PALM LASER PLS2 PLS Lab Technicians A1 A2 B1 B2 15 PLS Pacific Laser Systems garantiert dem ersten Käufer das dieses Produkt frei von Mängeln an Material und Arbeit ist wenn es innerhalb von zwei jahren Kaufdatum normal verwendet wird Während der Garantieperiode und gegen Vorlage der Kaufquittung wird das Produkt von PLS reparier...

Page 9: ...1 CFR Subcapítulo Estas etiquetas están adheridas a todos los productos láser de PLS No deben quitarse ni borrarse PLS 2550 KERNER BLVD SAN RAFAEL CA 94901 WWW PLSLASER COM EVITE LA EXPOSICIÓN RADIACIÓN LÁSER EMITIDA A TRAVÉS DE ESTA ABERTURA PLS2 Palm Laser DEL BOTÓN ON OFF LED PPLS2 CUMPLE LOS ESTÁNDARES DE FUNCIONAMIEN TO DE LA FDA 21 CFR SUBCAPÍTULO J NÚMERO DE SERIE MFG D PRECAUCIÓN RIESGO DE...

Page 10: ...ales y mano de obra en condiciones normales de trabajo durante un perio do de un año desde la fecha de adquisición Durante este periodo de garantía y tras pre sentación de prueba de compra el producto será reparado o sustituido por el mismo producto o por un modelo similar según nuestro criterio sin cargos por piezas o mano de obra a través de PLS El comprador correrá con los gastos de envío embal...

Page 11: ...AÎNER UNE EXPOSITION À DES RADIATIONS DANGEREUSES Le PLS2 est conforme aux normes de performances américaines FDA normes 21 CFR sous chapitre J Ces étiquettes sont collées sur tous les appareils laser PLS Elles ne doivent pas être enlevées ou abîmées PLS 2550 KERNER BLVD SAN RAFAEL CA 94901 WWW PLSLASER COM ÉVITER TOUTE EXPOSITION RADIATION LASER ÉMISE DEPUIS CETTE OUVERTURE PLS2 utilisation intér...

Page 12: ...ndirect ou important Cette garantie vous accorde des droits légaux spécifiques qui pourront s appliquer en plus d autres droits locaux A D C B Cible 1 Cible 2 PALM LASER PLS2 PALM LASER PLS2 Techniciens de Laboratoire PLS A1 A2 B1 B2 15 Si le niveau et le plomb sont conformes aux spécifications l équerre le sera également Nous vous recommandons de vérifier périodiquement votre appareil PLS2 afin d...

Reviews: