power  applied  after  a  certain  period  of  delay.

  air  compressor  is  loaded  and  pressure  inside  gas 

tank  begins  to  increase.  When  increased  air  pressure  is  more  than  higher  pressures  limit  (value  of 

unload  pressure),  electromagnetism  valve  for  loading  is  de-energized  and  electromagnetism  valve  for 

discharging is energized, meanwhile, the air compressor operates without load. If air pressure decreases 

to set lower pressure limits (value of load pressure), the electromagnetism valve for loading is energized 

again and electromagnetism valve for discharging is de-energized. Air compressor operates normally to 

increase  pressure  in  air  tank.  If  the  unload  run  time  exceeds  the  set  delay  time  of  non-load,  the 

compressor  will  automatically  stop  motor’s  operation  to  achieve  automatic  shutdown  after  works 

without  load  for  long  time.  Only  when  pressure  decreases  to  lower  pressure  limits,  the  motor  start 

operation according to course of starting, then circularly repeat this step.   

. Manual loading/unloading under automatic status                   

When  compressor  in  automatically  runs  state  and  runs  at  unload  operation,  press  down  load  or 

unloading button , the electromagnetism valve for loading joggles a little and comes back to unloading 

status;  if  the  pressure  is  less  than  relief  pressure,  the  electromagnetism  valve  for  loading  is  energized 

and  it  returns  to  unloading  status  until  gas  supply  pressure  becomes  larger  than  relief  pressure  and 

device  is  at  loading  status.  Unloading  is  performed  when  press  down  unloading  button  “

S

”.  If  the 

pressure  is  higher  than  loading  pressure,  the  electromagnetism  valve  for  loading  is  de-energized  and 

turns to status of loading until gas supply pressure is less than loading pressure. If pressure is less than 

loading pressure, the unloading button do not function. 

. Normal shutdown:                 

Press  the  button  ,  the  load magnetic  valve  will  loss  power  and the  unload magnetic will  be applied 

with power, after a while of delay (stop delay), the motor contactor will loss power, the host and fan will 

stop  running,  after  the restarting  delay  completed,  the unload magnetic will  loss  power.  Only  pressing 

the button could restart the motor.   

. Control of preventing frequent starting   

Press stop button to stop operation; Air compressor can not be started up immediately after shutdown 

due to operation  without  load  for  long  time or  failure  shutdowns,  and  it  can  be  started  up  again  when 

remaining delay time is zero which the time display window of the controller in a variety of shutdown 

state shows. 

2、. Remote automatic control  

Remote  automatic  control  and  local  automatic  control  are  basically  same,  but  the  difference  is  that 

starting up or stopping of devices can be achieved by means of control of remote switch.   

3、 Local manual control     

Control  of  starting  and  stopping  are  same  as  automatic  control,  but  device  is  in  status  of  unloading 

operation after finish starting up and loading is carried out by pressing down loading and unloading button   

to load. When gas supply pressure is more than relief pressure, the device unloads automatically. If doesn’t 

press  loading,  unloading  button,  the  device  will  operate  with  unloading  until  stops  without  load.  During 

unloading, press loading and unloading button to load. During loading, press loading and unloading button 

to unload. 

4、Remote Manual Control  

The  remote  automatic  control  is  almost  the  same  as  the  local  manual  control,  the  only 

difference is that the start and stop of the unit is controlled by remote control. 

 

5、 Network control  

 

Summary of Contents for MAM-880

Page 1: ...hen Plot electronic Co Ltd Address Sixth floor twenty fifth building TIAN JIAN industrial estate SHANG BAO road FU TIAN district SHEN ZHEN Telephone 0755 83172098 83172068 Postal code 518034 Fax 0755...

Page 2: ...lly before switch up Earthing terminal of this body part shall be earthed correctly the third type of earthing to increase product s capacity of resisting signal noise Motor s rated current current fo...

Page 3: ...matic control 17 3 Local manual control 17 4 Remote Manual Control 17 5 Network control 17 6 Temperature control of fan 18 7 Failure shutdown and emergency shutdown 18 6 Early warning and prompts 18 1...

Page 4: ...d by pressing this button when data are modified Menu is moved upwards when menu is selected Move down button Descending button Data at current position is descended by pressing this button when data...

Page 5: ...to move the black cursor to RUN PARAMETER press enter button to pop up submenu WELCOME USING SCREW COMPRESSOR AIR T 20 AIR P 0 60MPA NORMAL STOP C001 REMOTE RUN PARA USER PARA FACTORY PARA CALBR PARA...

Page 6: ...rimary menu press the move button to move the black slider to the USER PARA menu press the shift button to switch to the following menu Move the cursor to the P T SET menu then press enter button to s...

Page 7: ...P Control the stopping of the fan TIME SET HOST START 0008S When using the controller to protect the motor it is required that the time set here will not meet the impulse starting current of the motor...

Page 8: ...ration SEQ LOAD MPa The main air compressor searches for one device in the interlocking network for loading or starting when main air compressor s gas supply pressure is less than the value set here d...

Page 9: ...press set button switch to the factory parameters of the interface as follows Factory parameters run time phase sequence protection Frequency Selection and the time need check super password to chang...

Page 10: ...er frequency HIGH VOL V Controller detects the voltage higher than the set value the shutdown protection reported voltage is too high Set this value to 0000 the high voltage function is no function LO...

Page 11: ...A Displays the current controller sampling current values This value is the real value can not be set F A N A TARGET CUR 0000 Enter the current value the controller will detect user input value divide...

Page 12: ...cturers Password factory fixed ___________ Permissions Allows users to modify all the parameters the user password and the parameters of some manufacturers manufacturers selling password 6 Calibration...

Page 13: ...ors and operation time shown in following table table 2 1 1 when motor s working current is larger or equal to from 1 2 times and 3 0 times of set current Iactual Iset Time parameters 1 2 1 3 1 5 1 6...

Page 14: ...15 50 MAM880 200 80 200 40 100 MAM880 400 160 400 80 200 MAM880 600 5 100 600 50 300 4 Installation 1 Installation of transducer The transducer shall be installed at place where motor s line current...

Page 15: ...l dimensions of CT2 2 Controller Installation The controller is installed as plate Room should be left around controller for wiring The specific dimensions are as follows Figure 4 1 5 Controller struc...

Page 16: ...fan 15 terminals controls load valve 16 terminals controls angle shaped contactor 17 terminals controls star shaped contactor 18 terminals controls main contactor NOTE Eelectromagnetism coil shall be...

Page 17: ...ding until gas supply pressure is less than loading pressure If pressure is less than loading pressure the unloading button do not function Normal shutdown Press the button the load magnetic valve wil...

Page 18: ...filter Early warning for blockage of oil filter The controller can display the message on the text display to remind the operator that the air filter is blocked by checking the pressure difference swi...

Page 19: ...T 3 Non reversing Protection of Air Compressor When three phase supply phase sequence connected to the air compressor is not the same with that set for the controller the on site failure is displayed...

Page 20: ...power and contactors Overloaded Voltage too low tubes blocked Bearing Wear off or other mechanical failure or wrong set data etc Check the set data Voltage bearings tubes and other mechanical system...

Page 21: ...Temperature too high Bad vent condition Oil lacking etc Check the vent condition and lubricant amount etc Temperature Sensor Failure Cable off or PT1OO damaged Checking the wiring and PT100 Over Pres...

Page 22: ...Page 22 of 22 9 Electrical diagram 18 17 16 15 14 13 uc ua ub C1 RS 485 B A 1 FG 22 23 24 25 26 27 28 29 30 31 a CT2 21 20 19 2 3 4 5 6 7 8 9 10 b c A B C CT1 11 12...

Reviews: