CD-ROM Drive Set to Test Mode
Turn this switch OFF. The test mode is for factory use only. Always turn the drive OFF
before changing the setting of the switches.
Symptom
•
Low Performance of CD-ROM Application Software
Possible Cause and Solution
Drive Automatically Set to Standard Throughput (150KB/sec)
Plextor’s drives are designed to automatically switch from quad speed throughput
(600KB/sec) to double (300KB/sec) and then single (150KB/sec) speed when they
encounter a defective, damaged or poorly manufactured disc. The drive then will
continue to read data from the disk at double or single speed until a new read
command is transmitted to the drive. The drive will then attempt to return to quad
speed mode.
CHAPTER 13 ---- Troubleshooting
PX-43CH/PX45-CH OPERATION MANUAL
61