Object ID
Object name
Object Type
Access
Rights
Description
.1316.1.1.1.2.4.9 mdrmteTime
DisplayString
read-write
This is a time record that is
recovered from the Indoor
Unit's Real Time Clock
.1316.1.1.1.2.4.10 mdrmteNOVRAMInit
INTEGER
read-write
If activated, the
Nonvolatile memory is
initialised to a set of
default parameters
.1316.1.1.1.2.4.11 mdrmteFECBypass
INTEGER
read-write
This is primarily a
laboratory test entry used
to control whether the FEC
circuitry within the
.1316.1.1.1.2.4.12 mdrmteFECCorrectableSymbols INTEGER
read-write
This is primarily a
laboratory test entry used
to control the FEC
correction power - 20
parity symbols
.1316.1.1.1.2.4.13 mdrmteTribCode
DisplayString
read-write
This is a text entry code
(80 characters ie 40 bytes)
used to allow activation of
tributaries on the Indoor
Units.
.1316.1.1.1.2.4.14 mdrmteIndoorUnitBarCodeNumber
DisplayString
read-write
This is a text entry code
used to allow storage of
the Indoor Unit's bar code
serial number (as seen on
the outside of the
.1316.1.1.1.2.4.15 mdrmteIndoorUnitPCBrevision INTEGER
read-write
This is a numeric entry
code used to reflect the
PCB revision number and
modification status.
.1316.1.1.1.2.4.16 mdrmteLocation
DisplayString
read-write
The station location is
stored in the Indoor Unit in
nonvolatile memory
.1316.1.1.1.2.4.17 mdrmteOnePlusOne
INTEGER
read-write
Enables 'one-plus-one'
dual-redundant (non-
hitless) operation
.1316.1.1.1.2.4.18 mdrmteMaxTribs
INTEGER
read-only
How many tribs can be
used with the current trib
code.
.1316.1.1.1.2.4.19 mdrmteDefaultConfig
INTEGER
write-only
Allows one to set one of
four default-configurations.
.1316.1.1.1.2.4.20 mdrmteTotalTribs
INTEGER
read-only
How many tribs in total on
this version of IDU
motherboard.
.1316.1.1.1.2.4.21 mdrmteCustomConfigSet
INTEGER
read-write
Changes the way in which
the default configurations
work by pre-loading
.1316.1.1.1.2.4.22 mdrmteFpgaVersion
INTEGER
read-only
Firmware version of the
FPGA.
.1316.1.1.1.2.4.23 mdrmteOuCommsRate
INTEGER
read-write
Data-rate of the ethernet
link between the IU and
the OU.
.1316.1.1.1.2.4.24 mdrmteHdlcRateCap
INTEGER
read-write
Maximum Data-rate of the
HDLC link between the
IU's (Mbit/sec + 1)
.1316.1.1.1.2.4.25 mdrmteOUSerialNo
DisplayString
read-only
The Outdoor Unit serial
number is programmed
into the OU at time of
manufacture and is read
via the
.1316.1.1.1.2.4.26 mdrmteApVersion
DisplayString
read-only
The Firmware version
number of the Atmel
processor
.1316.1.1.1.2.5 mdrmteFirmware
.1316.1.1.1.2.5.1 mdrmteFTPServerStatus
INTEGER
read-write
This allows
activation/deactivation of
the FTP server that runs in
the Indoor Unit and is
.1316.1.1.1.2.5.2 mdrmteFlashNewFirmware
INTEGER
read-write
This entry determines the
time when the new version
of firmware will be
activated
Summary of Contents for MDR2400-SR
Page 13: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 13...
Page 41: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 41 This page is left blank intentionally...
Page 67: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 67...
Page 68: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 68...
Page 70: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 70...
Page 73: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 73...
Page 74: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 74...
Page 75: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 75...
Page 79: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 79...
Page 128: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 128...