INSTALLATION AND COMMISSIONING
EasyReach
User Manual
12
1H90941
Initial Switch-On
Verify that the radiated emission regulations are not exceeded by either
calculation using Equation 1 or using the EasyReach Element Manager. If
necessary the output power can be adjusted using the EasyReach Element
Manager.
Equation 1
Use to calculate radiated emissions
EIRP = Output Power – Cable Antenna Gain
Ensure that the equipment is set up according to Figure 1 (see page 4).
It is not necessary to interface a PC to the
EasyReach
unit unless the user
requires either to monitor the system operation or to re-configure the control and
monitoring parameters – see “System Control and Monitoring” below, and
“Control and Configuration Using
EasyReach
Element Manager” on page 22.
Ensure that the antennas at both sites are pointing to within ±6 degrees of the
other site in both the vertical and horizontal planes.
Switch on the power to the equipment at both ends of the link.
The four front-panel status indicator LEDs should all be green (although they
may not be if the antenna alignment is not yet accurate enough).
Perform the antenna alignment procedure detailed on page 13.