Supply Connection
AC Power Version
Connect the unit to mains power using the supplied mains power cable.
DC Power Version
A mating connector is supplied for the connection of DC power.
The DC power option provides isolated positive and negative power terminals
and a chassis ground terminal. It is recommended that the ground rail of the
supply be connected to the chassis ground.
For example, if a -48V supply is used, the -48V rail will be connected to "-" and
the 0V rail will be connected to "+" and also to the chassis ground terminal.
RF Frequency Variants
EasyReach
units come in two different frequency variants, and with
complementary transmit/receive frequencies for each variant. The frequencies
of the variants are listed in Table 1.
In setting up a radio link consisting of frequency variant 1 units, the unit at one
end of the link must be a 1a variant and the unit at the other end of the link must
be a 1b variant. Similarly, if frequency variant 2 units are used, one unit must be
a 2a variant and the other one a 2b.
Table 1
RF Frequency Variants
VARIANT
TX FREQUENCY
RX FREQUENCY
1a
2412 MHz
2452 MHz
1b
2452 MHz
2412 MHz
2a
2426 MHz
2464 MHz
2b
2464 MHz
2426 MHz