13
Troubleshooting
Problem:
Cause:
Solution:
1. Lift will not operate at all:
Low Battery (Lift) – Red or
amber LED on the receiver
Damaged Battery (Lift) – Red
LED on the receiver
Dead Battery (Transmitter)
Remote Locked
Battery Fuse blown
Battery Push button Switch in
the off (out) position
Recharge Battery
Replace Battery*
Replace Battery
3V Lithium 2032
Push unlock button for
2 seconds
Replace Battery Fuse
Depress push button
switch into the on (in)
position
2. The seat will not raise or lower.
The seat will not rotate.
Low battery (Amber LED on
Receiver)
Battery not installed properly
Receiver malfunction
Recharge battery
Reinstall battery
Replace Receiver*
3. The seat’s motion isn’t smooth or
sticks at a certain point during travel.
Excessive wear to bearings
Excessive wear to Actuator
Replace bearings*
Replace Actuator*
4. The seat travels much slower
than normal.
Low battery
Defective or worn-out battery
Recharge battery
Replace battery*
5. The lift makes much more noise
or unusual noises during operation.
Excessive wear to bearings
Pivot points galling
Replace bearings*
Oil pivots with light oil
(3-1)
6. Battery will not charge:
Charger Fuse Blown
Bad Battery (red LED on
charger – not turning orange
or green in 4 hours or less)
Replace Charger Fuse
Replace Battery*
*Please contact your local distributor or Spectrum Customer Service to order parts 406.532.6321