888-2408-002
2-23
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
A series resistor and LED can also be used for extended status indications.
Maximum external supply voltage should not 28Vdc.
NOTE:
Maximum status line current is 25 mA. If the output is used to drive a
small printed circuit board type relay, check current requirements for
relay coil and be sure to install a circuit protection diode across the
coil. A 1N4004 or equivalent will work.
Figure 2-12 shows typical remote/extended control and status connections.
Figure 2-12
Remote/Extended Control and Status Connections