![Platinum 5500 R3-S2B User And Installation Manual Download Page 44](http://html1.mh-extra.com/html/platinum/5500-r3-s2b/5500-r3-s2b_user-and-installation-manual_1566098044.webp)
Installation and user guide PLATINUM
®
inverter 5500 R3-S2, 7000 R3-S2, 8000 R3-S2, 9000 R3-S2
9 Technical data
Input variables
5500 R3-S2
7000 R3 -S2
8000 R3 -S2
9000 R3 -S2
Max. PV power
5,800 Wp
6,900 Wp
8,000 Wp
9,000 Wp
Max. DC power (cos
ϕ
= 1)
5,200 W
6,200 W
7,200 W
8,300 W
MPPT voltage range (MPPT1 / 2)
150 – 720 V / 150 – 720 V
150 – 720 V / 150 – 720 V
Max. input voltage (per MPPT)
900 V
900 V
Max. MPPT input current (MPPT1 / 2)
9,5 A / 9,5 A
9,5 A / 9,5 A
Number of string inputs (MPPT1 / 2)
1/1
1/1
Number of MPP trackers
2
2
Short circuit current (MPPT1 / 2)
14 A / 14 A
14 A / 14 A
Reverse voltage protection / earth fault monitoring
Isolation control
Isolation control
Output variables
5500 R3 -S2
7000 R3 -S2
8000 R3 -S2
9000 R3 -S2
Nominal power (cos
ϕ
= 1)
5,000 W
6,000 W
7,000 W
8,000 W
Nominal current
3 x 7.2 A
3 x 8.7 A
3 x 10.1 A
3 x 11.6 A
Max. apparent power
5,600 VA
6,700 VA
7,800 VA
8,900 VA
Max. AC current
3 x 9,9 A
3 x 11.9 A
3 x 13 A
3 x 13.1 A
Fuse protection on the AC side
3 x 16 A
3 x 16 A
Min. start power
20 W
20 W
Mains voltage
3 AC 230 V / 400 V + N (+/– 20 %)
3 AC 230 V / 400 V + N (+/– 20 %)
Mains frequency
50 Hz (+/– 5 %)
50 Hz (+/– 5 %)
Feed-in/monitoring phases
3 feed-in / monitoring phases
3 feed-in / monitoring phases
Max. network impedance permitted (Z
max
)
–
–
–
402 m
W
Standby consumption
1 W
1 W
Short-circuit strength / earth fault monitoring
(AFI)
Yes
Yes
Power factor (cos
ϕ)
0.7 ind ... 0.7 cap
0.7 ind ... 0.7 cap
Max. short circuit current (max. duration: 5 ms)
120 A
120 A
Inrush current
4 A
4 A
Ground fault monitoring
RCD
RCD
Efficiency
5500 R3 -S2
7000 R3 -S2
8000 R3 -S2
9000 R3 -S2
Max. efficiency
98.5%
98.5%
EU efficiency rate
98.1%
98.2%
Type name
5500 R3-S2B
7000 R3-S2B
8000 R3-S2B
9000 R3-S2B
44