40
Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
Menu
Phase Balancer
Error Off
In the event of failure of an inverter, the other two inverters
connected via the phase balancer are also isolated from the
network.
Error reduce
In the event of failure of an inverter, the other two inverters
connected via the phase balancer limit the AC power level to the set
unbalanced load.
If the feed-in power of an inverter is reduced due to unbalanced load, no
status message is displayed on the inverter.
6.5.7 Service menu POWER REDUCTION
This menu can only be changed for a period of 4 hours after initial
configuration.
Power reduction
Maximum
power
Enter the maximum power for this inverter according to the
specifications of the network operator.