Dingo Pup User Guide
14
the Pup. If it is not present,
check the cable connections
from the Dingo to the Pup
and wait for 2 minutes.
There will also be entries for
SWH5 under LOAD, IN and
OUT.
If the Dingo is using
PROG=4, then the Dingo
ESET must be set correctly.
In Dingo program 4, the
preloaded default setting for
each pup is ESET/SW=0.
This is correct for using
the Pup’s charge terminal
for charge control (or the
Pups load terminal for shunt
regulation). If using the Pups
only for charge control, it
should not be necessary to
change the ESET/SW setting.
Connecting the Pup to the Dingo
If the program selection
(PROG) on the Dingo is
set in the range 0 through
to 3, then the Dingo is
automatically
configured
for using the Pups as charge
controllers.
The Dingo may take a short
time to discover a new Pup.
When the Pup is discovered,
there will be an entry on the
Dingo for the charge and
load current and external
amp hours.
For example, if the Pup
address is set to 5, then in
the Dingo CHRG sub menu,
there will be an entry called
SWH5. This is the charge
current in the Pup at address
5, as seen by the Dingo.
If the CHRG/SWH5 entry
is present, it confirms that
the Dingo has recognised