Retrigger
The Retrigger function sets a determined number of repetitions for each envelope. It is
accessible via [
SOUND SET
> RETRIGGER].
Controls and features:
-
Time distribution
[DISTR: LIN; LOG; EXP]. Determines how the time is distributed.
With LIN (linear) each step distance will be the same. With EXP (exponential) the
beginning steps will be more spread than the latest ones. With LOG (Logarithmic) the
latest steps will be more spread than the beginning ones.
-
Retrigger pattern
[RETRIGGERS]
.
Sets the step pattern that will be executed after
the initial envelope. If only the first retrigger is ON there will be 2 envelopes, the
normal, and the retriggered one. There are 12 possible retriggers, and the Slot
buttons are used to configure the pattern.
-
Time
(
RETRIG1
and
RETRIG2
). Sets the time between each repetition.
If Hold is set to External the Hold will be performed on all the retriggers covered by the Gate
time (see Figure 2). If it is Internal it will be repeated to each retrigger (see Figure 1,
HOLD
=
0)