INSTALLATION MANUAL
Hot Box REMOTE
•
Do not install the device in areas with a capacity of less than 118 m
3
/ 4167 ft
3
(45
m
2
/ 484 ft
2
with a height of 2.6 m / 8.53 ft).
•
Do not install the device in areas of large drafts of air, near fans, vents, etc.
•
Do not place the device in close proximity to sources of humidity.
•
It is obligatory to have a carbon-dioxide (CO
2
) or dry chemical extinguisher placed
nearby the device.
•
Installation of the device must provide an easy removal of the device for service.
•
The room in which the device will be installed must have efficient ventilation to
ensure air exchange in the room at least once per hour.
•
Do not start the device before a complete and proper installation.
•
Do not fill the fuel container before placing the product into its final position.
•
Do not obstruct the ventilation slots and/or ventilators.