INSTALLATION MANUAL 

Hot Box REMOTE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not install the device in areas with a capacity of less than 118 m

3

 / 4167 ft

3

 (45 

m

2

 / 484 ft

2

 with a height of 2.6 m / 8.53 ft). 

 

Do not install the device in areas of large drafts of air, near fans, vents, etc. 

 

Do not place the device in close proximity to sources of humidity. 

 

It is obligatory to have a carbon-dioxide (CO

2

) or dry chemical extinguisher placed 

nearby the device. 

 

Installation of the device must provide an easy removal of the device for service. 

 

The  room  in  which  the  device  will  be  installed  must  have  efficient  ventilation  to 
ensure air exchange in the room at least once per hour. 

 

Do not start the device before a complete and proper installation. 

 

Do not fill the fuel container before placing the product into its final position. 

 

Do not obstruct the ventilation slots and/or ventilators. 

 